MP500/4N-8-16 Programming
129
Code or input ID
The meaning of the code depends on the event.
Event
Code
Description
For arming events
000
Event generated by Installer code, Timed Programmer or Hi-
Connect
To identify a user or a key
001
Event generated by the master user code
002 ÷ 063
Event generated by the user code 2 ÷ 63
101 ÷ 164
Event generated by key 1 ÷ 64
2<radio.exp.num>
<rem.ctrl.num.>
Event generated by remote control of a radio expansion module
To indicate the logical number of the
concerned input
001 ÷ 128
To
identify
the
keypad
which
generated a function key event
101 ÷ 108
Event generated by keypad 1 ÷ 8
To identify the device which generated
the tamper alarm
000
Event generated by tamper or SAB input of control panel
101 ÷ 108
Event generated by tamper of keypad 1 ÷ 8
401 ÷ 415
Event generated by tamper of an expansion module or
supplementary power unit
501 ÷ 502
Event generated by the tamper of a radio expansion module
To identify the device which generated
the failure alarm consequent to loss of
communication
101 ÷ 108
Event generated by no communication of keypad 1 ÷ 8
301 ÷ 316
Event generated by no communication of reader 1 ÷ 16
401 ÷ 415
Event generated by no communication of expansion of
supplementary power unit 1 ÷ 16
501 ÷ 502
Event generated by no communication of a radio expansion
module
To identify the device which generated
the low battery alarm
000
Event generated by the control panel battery
401 ÷ 415
Event generated by the battery of a supplementary power unit
1 ÷ 16
5xx
Event generated by the battery of a radio device
(*)
To identify the device which generated
the lack of power alarm
000
Event generated by "lack of power" on control panel
401 ÷ 415
Event generated by "lack of power" on a supplementary power
unit 1 ÷ 16
Table 17 - ID code or input with IDP protocol
(*) Encoding
(For more information see dedicated manual).
Summary of Contents for MP500/16