MP500/4N-8-16 Programming
10 - TABLES
10.1 VOCAL ALARM MESSAGES
The following tables show all the vocal messages (both pre-recorded and not) for the possible events and show which messages can
be customised by recording a personal message over it. Further details are provided for each message type with indication of how to
listen to it.
The basic message must be recorded. It is in common to all events and alarms and it is 10 seconds long.
The maximum length of all other messages is 4 seconds.
Event/alarm
Message
Customisable
Mode 4
Generated for
More
details in
Mode:
Burglar alarm
Burglar alarm
■
Opening of a burglar alarm input
2, 3, 4
Tamper alarm
System tamper
■
Device tampering (tamper, SAB or no
communication)
Input imbalance
2, 3, 4
Panic
Panic
Opening of a panic alarm input
2, 3, 4
Silent panic
Opening of a silent panic alarm input
2, 3, 4
Pressing a function key on the keypad
Pressing key 2 on the remote control (if
programmed)
Hold-up alarm
Attack in progress
■
Entering a hold-up code
2, 3, 4
Opening of a hold-up alarm input
Fire alarm
Fire alarm
■
Opening of a fire alarm input
2, 3, 4
Pressing a function key on the keypad
Pressing key 2 on the remote control (if
programmed)
Emergency alarm
Help needed
■
Opening of an emergency input or no
movement detected
2, 3, 4
Pressing a function key on the keypad
Pressing key 2 on the remote control (if
programmed)
Technological event
type 1 - 2 - 3
Technological service
■
Opening of a technological input 1 - 2 - 3
2, 3, 4
Failure alarm
from failure input
Input failure
Opening of a failure input
2, 3, 4
End of alarm from
failure input
Input restored
Closing of the failure input
2, 3, 4
Failure alarm
PSTN telephone line
Telephone line failure
Anomaly detected on PSTN telephone line
End of PSTN telephone
line failure
Telephone line
restored
Anomaly corrected on PSTN telephone line
GSM line failure alarm
GSM line failure
Anomaly detected on GSM line
End of GSM line failure
Telephone line
restored
Anomaly corrected on GSM telephone line
System failure alarm
System fault
Anomaly detected on the system
End of system failure
alarm
System fault restored
Anomaly corrected on system
Continuous lack of power
alarm
Mains power failure
No mains power in control panel for longer
than programmed time ("lack of power" time)
End of lack of power alarm
Electric line restored
Power restored to control panel
Low battery alarm
Battery fault
Flat or missing control panel battery
End of low battery alarm
Battery restored
Control panel battery charge restored
Arm partition(s)
Armed
Some partitions armed
2, 4
Disarm partition(s)
Disarm
Some partitions disarmed
2, 4
SIM expiry warning
SIM Card expiry
The first day of the month set for the
warning reached
Table 14 - Vocal messages for MP500/4N, MP500/8 and MP500/16 control panels