88
MEDEA Installation Manual
7.2
ABS box
PS515 power unit
(PS Type A)
Input voltage:
Output voltage:
Current consumption:
Current supplied:
Ripple:
Fuse:
Insulation class:
220-240
V~ +10% -15%
50/60 Hz 14,4
V
⎓
0.6 A
1.5 A
100 mVpp max
T2AL 250
V~
II 2500 V
Battery housing
12V 7.2 Ah / 12V 9Ah
Dimensions (W x H x D)
335 x 235 x 98 mm
Weight
1.25 kg
IP protection level
IP30 / IK06
EN50131 certification
Grade 3 Class II
7.3
Metal box
Power supply
(Ps type A)
Input voltage:
110-240 V
~
+10% -15%, 50-60 Hz
Output voltage:
14.4 V
⎓
Current consumption:
1 A max.
Current supplied:
3.4 A
Ripple:
120 mVpp max
Short-circuit protection:
Self-resetting
Insulation class:
I 2500 V
Battery housing
12 V 18 Ah
Dimensions (W x H x D)
435 x 320 x 90 mm
Weight
5.2 kg
IP protection level
IP30 / IK06
EN50131 certification
Grade 3 Class II
7.4
EP708 expansion module
Nominal power voltage
13.8 V
⎓
Working voltage
… V
⎓
Rated current consumption at 13.8 V
⎓
(single-balanced) 36.5 mA
Max. current deliverable to PrIO terminal
50 mA
Max. current deliverable from all terminals
750 mA
Dimensions (L x H)
89 x 75 mm
Maximum bus length
(cable cross-section 2x0.75 mm
2
power 2x0.22
mm
2
data)
500 metres
EN50131 certification
Grade 3 Class II
Summary of Contents for MEDEA