MEDEA Installation Manual
23
CPU BOARD LAYOUT KEY
A
OPER
GREEN LED
On = Normal operation
Off = Board not working
Flashing = System start
R**
+
Power positive (13.8
V
⎓
)
COM
GREEN LED
On = Board not working
Off = Board not working
Flashing = Normal operation
A
Data transmission/reception BUS A
+3V3
RED LED
Logic present power (+3.3 V
⎓
)
B
Data transmission/reception BUS B
CLOUD
GREEN LED
On = Cloud connected
Off = No connection to the Cloud
-
Power negative (GND)
RUN
RED LED
On = Control unit not working
Off = Control unit not working
Flashing = Normal operation
S
+
Power positive (13.8
V
⎓
)
B
PWR
RED LED
Board power supply present (14.4m
V
⎓
)
A
Data transmission/reception BUS A
C
SW2-1
DIP switch ON = Maintenance in progress
DIP switch OFF = Normal operation
B
Data transmission/reception BUS B
SW2-2
DIP switch ON = Reset codes
DIP switch OFF = Normal operation
-
Power negative (GND)
SW2-3
DIP switch ON = Total reset
DIP switch OFF = Normal operation
T
SR
Power output without back-up (14.4
V
⎓
)
SW2-4
DIP switch ON = Not allowed
DIP switch OFF = Normal operation
+V1
Power output positive (13.8
V
⎓
)
D
RES
Reset button if pressed for 5 sec
-V1
Output power negative (GND)
E
EXC
Jumper inserted = Tamper bypassed
NC1
Output 1 - relay, contact normally closed
F
TAMPER
Tamper connector
NO1
Output 1 - relay, normally open contact
G
*
+
Power positive (13.8
V
⎓
)
C1
Output 1 - relay, common contact
A
Data transmission/reception BUS A
U2
Output 2 - electric
B
Data transmission/reception BUS B
SAB
SAB input - single-balanced
-
Power negative (GND)
U
+V2
PrIO power positive (13.8
V
⎓
)
H
+BAT
Back-up battery connection cable 12
V
⎓
7Ah MEDEA /32 CPU
9Ah / 18Ah CPU MEDEA /64 and /160
-V2
PrIO power negative (GND)
-BAT
IN1
Input 1, referred to positive
I
+PS
Board power positive (14.4
V
⎓
)
IN2
Input 2, referred to positive
-PS
Board power negative (GND)
IN3
Input 3, referred to positive
J
USB-B
USB connector type B. For local connection of a PC
for programming
IN4
Input 4, referred to positive
K
*
USB-A
USB type A connector. For the connection of a USB
memory device for software updates
IN5
Input 5, referred to positive
L
LAN
RJ45 connector. For connecting the control unit to a
LAN or modem/router
IN6
Input 6, referred to positive
M
OPTO1
Connector for optional interface
V
*
+V2
PrIO power positive (13.8
V
⎓
)
N
OPTO2
Connector for optional interface
-V2
PrIO power negative (GND)
O
OPTO3
Connector for optional interface
P7
PrIO 7 - programmable input/output
P
Bus
RED LED
Flashing = Bus communication
P8
PrIO 7 - programmable input/output
Q
*
BATT
Clock-calendar back-up battery
Table 11 - MEDEA CPU elements
*
CPU MEDEA /64 and MEDEA /160 CPU only
*For connection of the ER700-RF wireless expansion interface
Summary of Contents for MEDEA