CARATTERISTICHE TECNICHE 

 
• Tensione nominale di alimentazione ..................12 o 24 V─ 
• Tensione di funzionamento ................................10,5 ÷ 30 V─ 
• Assorbimento max.in allarme .............................260 mA  
• Frequenza (doppia tonalità): ..............................3500 – 3700 Hz 
• Pressione acustica ............................................110 dB(A) @ 1m  
• Microswitch antiapertura ....................................1A @ 24V 
• Temperatura di funzionamento  .........................-10°C ÷ +55 °C 
• Grado di protezione involucro  ...........................IP41 
• Dimensioni (L x H x P) .......................................145 x 100 x 42 mm 
 

Modello HPA100 

in contenitore bianco

Modello HPA100F 

in contenitore rosso per uso segnalazione antincendio.

 

 
Disponibile versione autoalimentata HPA100A.

 

 

INSTALLAZIONE 

 
Per installare le sirene famiglia HPA100 fare quanto segue: 
1) Rimuovere i tappi di copertura e svitare le viti. 
2) Utilizzare  una  delle 

predisposizioni  “A” 

per  il  passaggio  cavi 

evidenziate  in  figura  sfondando  la  parete.  Se  necessario  rimuovere  la 
scheda elettronica agendo sui due 

gancetti

 

“B”. 

Sono anche disponibili 

delle  predisposizioni  per  ingresso  cavi  da  canalina  sui  lati  del 
contenitore. 

3) Fissare il fondo della sirena utilizzando i 

fori “C”

 in caso di fissaggio a 

parete o i

 

fori “D” 

in caso di fissaggio su scatola da incasso. 

4) Collegare la sirena alla centrale. 
5) Richiudere il coperchio della sirena. 

 
CONNESSIONI 

  

 

+  

POSITIVO DI ALIMENTAZIONE 

NEGATIVO DI ALIMENTAZIONE 

TAMPER 

CONTATTO ANTI-APERTURA 

 

 
TECHNICAL FEATURES 

 
• Rated supply voltage ........................................ 12 or 24 V─ 
• Operating voltage ............................................. 10,5 ÷ 30 V─ 
• Max current in alarm ......................................... 260 mA  
• Working frequency (dual tone) .......................... 3500 – 3700 Hz 
• Acoustic pressure ............................................. 110 dB(A) @ 1m  
• Anti-opening/anti-removal micro-switch ............. 1A @ 24V 
• Working temperature  ....................................... -10°C ÷ +55 °C 
• Case protection degree  .................................... IP41 
• Dimensions (w x h x d) ...................................... 145 x 100 x 42 mm 
 
Model 

HPA100

 in white casing. 

Model 

HPA100AF

 in red casing for fire signalling.

 

 
Also available a self-powered model HPA100A.

 

 

INSTALLATION 

 
To install the HPA100 family sounders perform the following operations: 
1)  Remove the screw caps and release the screws. 
2)  Utilize one of the planned cable entry holes

 

“A”

. If necessary release 

the  electronic  board  from  the  ledge 

“B” 

and  remove  it.    There  are 

other  pre-fractured  holes  on three  side  of  the  box  for  cable trunking  / 
rigid pipe. 

3)  Fix the bottom of the siren utilizing 

“C”

 holes in case of wall mounting, 

or 

“D”

 holes in case of 3 modules box. 

4)  Lay the sounder to the control panel. 
5)  Close the sounder cover. 

 
 
CONNECTIONS 

 

+  

POWER SUPPLY: POSITIVE POLE 

POWER SUPPLY: NEGATIVE POLE 

TAMPER 

TAMPER CONTACT 

 

ELKRON è un marchio commerciale di URMET S.p.A. 
ELKRON is a trademark of URMET S.p.A. 
Via Bologna 188/C – 10154 Torino (TO) – ITALY 
www.urmet.com 

 

DS80HP93-001B     LBT80644      

Tappi copertura / Screw caps

 

24 H

+

-

TAMPER

R

EL
E'

  D

I  

A

L

L

A

R

M

 N

O

R

M

A

L

M

EN

T

  EC
C

IT

A

T

O

 )

CENTRALE

H

P

A

1

0

0

C         NO       NC

+   SIR   -

CONTROL PANEL

R

EL
A

Y

 N

O

R

M

A

L

L

Y

  PO
W

ER

ED

 )

Made in CHINA

 

ELKRON 
Tel. +39.011.3986711 – FAX +39.011.3986703 

www.elkron.com

 -  mail to

[email protected]

 

Summary of Contents for HPA100

Page 1: ...VO DI ALIMENTAZIONE TAMPER CONTATTO ANTI APERTURA TECHNICAL FEATURES Rated supply voltage 12 or 24 V Operating voltage 10 5 30 V Max current in alarm 260 mA Working frequency dual tone 3500 3700 Hz Acoustic pressure 110 dB A 1m Anti opening anti removal micro switch 1A 24V Working temperature 10 C 55 C Case protection degree IP41 Dimensions w x h x d 145 x 100 x 42 mm Model HPA100 in white casing ...

Page 2: ... funciónamiento nominal 12 o 24 V Tensión de funciónamiento 10 5 30 V Absorción máx en alarma 260 mA Frecuencia de funciónamiento doble tonos 3500 3700 Hz Presión acústica 110 dB A 1m Tamper 1A 24V Temperatura de funcionamiento 10 C 55 C Grado de protección contenedor IP41 Dimensiones l x h x p 145 x 100 x 42 mm Modelo HPA100 in contenedor blanco Modelo HPA100F in contenedor rojo para uso alarma d...

Page 3: ...E LASTNOSTI Nazivna napetost 12 ali 24 V Obratovalna napetost 10 5 30 V Max tok v alarmu 260 mA Delovna frekvenca dual tone 3500 3700 Hz Zvočni tlak 110 dB A 1m Zaščita mikro stikalo proti odprtju odstranitvi 1A 24V Delovna temperatura 10 C 55 C Stopnja zaščite ohišja IP41 Dimenzije Š x V x G 145 x 100 x 42 mm Model HPA100 v belem ohišju Model HPA100F v rdeči barvi za signalizacijo požara Na voljo...

Page 4: ...e que ce produit ne doit pas être éliminé avec vos autres déchets ménagers Au lieu de cela il est de votre responsabilité de vous débarrasser de vos équipements usagés en les remettant à un point de collecte spécialisé pour le recyclage des déchets des équipements électriques et électroniques DEEE La collecte et le recyclage séparés de vos équipements usagés au moment de leur mise au rebut aidera ...

Reviews: