Characteristic
Manual
Connection
Technical parameters
Description
167-02-001 Rev.: 0
Bell transformer
ZTR-10
EN
Output voltage AC 12 V
Supply terminals
Output voltage AC 4 V
Output voltage AC 8 V
AC 230 V
50 Hz
4V
12V
4VA
8V
ELKO
U
PRI
ZTR-10
Examples of usage
8V
12V
4VA
AC 230 V
50 Hz
4V
ZTR-10
L
N
PRI
U
Supply voltage:
Supply voltage tolerance:
Consumption without load:
Output voltage:
Max. testing voltage:
Storing temperature:
Fuse:
Consumption with load:
Output voltage-no load AC:
Max. load:
Operating temperature:
ZTR-10
AC 1 VA
AC 230 V / 50 - 60 Hz
AC 4 V
5.9 V
750 mA
AC 8 V
11 V
500 mA
AC 12 V
16 V
350 mA
short - circ.resistant
Weight:
343 g
AC 5 VA
-15 %; +10 %
4 kV
Protection degree:
IP20/40
Dimensions:
90 x 52 x 65 mm
Standards:
EN 61010-1; EN 60742
Max. cable size:
2.5 mm
2
-20 .. +60 C
o
-20 .. +50 C
o
4VA
AC 230 V
50Hz / 60Hz
U
PRI
4V
8V
12V
ELKO
Tovarni 1613, Holesov 769 01, Czech Republic
Tel.: + 420 573 395 114-115; Fax: + 420 573 399 160
e-mail: [email protected], www.elkoep.com
Informations about this products you can find on:
www.elkoep.cz/ztr10e.htm
Device is designed for 1-phase AC 230V connection and must be installated according standard valid in the existing country.
Connection according to the details in this direction.
Installation, connection, setting and servicing should be installed by qualified electrician staff only, who learn this instruction and functions of device. For right device protection
should be fronted-end certain element. Before starting installation must be main switch in position "SWITCH OFF" and device should be out of voltage. Don´t install device to
suppliers surcharge electro-magnetic interference. By right installation of device is provide good air circulate to don´t pass maximal operating temperature,in case of higher
ambient temperature and permanent working. For installation and setting use screw-driver cca 2 mm. The device is full-electronic - installation should be effected according to this.
Function without problems is too dependent on previous type of transportation, storing and manipulation. In case of any vestige of destruction, deformation, non-function or missing
part, don´t install and made claim to seller. Product may be, after passing operating time, disassembled, recycled or puted on protected tip.
- 3-MODULE, DIN rail mounted
- Supply: AC 230 V
- Universal power supply with AC output voltage
- Short-circuit resistant
- General usage - e.g. supply of door bells, electric locks, etc.
- Output voltage: AC 4 - 8 - 12 V
- Double output terminals