Elko iNELS Air AirCFS-100L Manual Download Page 1

1 / 4

AirCFS-100L

02-45/2018 Rev.: 0

4

Click!

2b

1

+

-

3

9

1

3

4

5

4

2

8

6
7

10

+

-

Characteristics 

Description

EN

General instrucions

•  The AirCFS-100 is designed to measure temperature, relative humidity and atmo-

spheric pressure.

•  The device incorporates the  IP65 design, so it is possible to use it in agriculture in 

outdoor areas (down sensor), e.g. vineyards, orchards ...

•  It is also suitable for use in harsh indoor areas, which require greater protection of 

the device, for example. Greenhouses.

•  With the wireless solution and  LoRa communication, it can communicate instantly 

to your chosen location and be operated immediately.

•  Data  is sent to the server from which it can be subsequently displayed as a smart-

phone, application, or Cloud notifi cation

•  Anti-sabotage: If access to the device is unauthorized, a message is immediately 

sent to the server.

•  Power supply 1x 3.6 V batteries SAFT.

•  Battery power can be sent to the server when it is powered by a battery.

Cloud app assignment

It is done in your Smartphone application. Enter the relevant information on the product 
cover into the application.

Internet of Things (IoT)

• The IOT wireless communications category describes the Low Power Wide Area 

(LPWA).  This  technology  is  designed  to  provide  full-range  coverage  both  inside  and 
outside buildings, energy-saving and low-cost operation of individual devices. The 
LoRa network is available to use this standard.

LoRa network information

•  The network is bidirectional and its communication uses free frequency band.

•  865 - 867 MHz 

India

•  867 - 869 MHz  

Europe

•  902 - 928 MHz 

North America, Japan, Korea

•  The advantage of this network is the possibility of freely deploying individual stations 

in local locations, thus strengthening their signal. It can therefore be used effi

  ciently in 

company premises or, for example, in local parts of cities.

•  For more information on this technology, please visit www.lora-alliance.org.

Caution for proper operation:

•  Products are installed according to the wiring diagram given for each product.
•  For proper device functionality, it is necessary to have suffi

  cient coverage of the selec-

ted network at the installation site.

•  At the same time, the device must be registered in the network. Successful device re-

gistration on a given network requires a charge for traffi

  c.

•  Each network off ers diff erent tariff  options - it always depends on the number of me-

ssages you want to send from your device. Information on these tariff s can be found in 
the current version of the ELKO EP pricelist.

Temperature, humidity, 
atmospheric pressure sensor

Made in Czech Republic

Assembly

1. Tamper

2. Programming pins

3. Button SET 

4. Hole for mounting on the wall 

Ø 4.3 mm / 0.2”

5. Antenna

6. Battery

7. LED indication

8. Sensor connection terminal

9. Sensor cover

10. Sensor

1. Using a fl at-blade screwdriver gradually slide it into one groove and the other in the lid 

and swing open the cover.

2. The product can be attached in two ways:

a) Directly on a fl at surface by gluing * - apply a suitable adhesive to the bottom of the 

base. Place the base in the desired location and let it dry.

b) Using a suitable fastener ** by screwing - drill holes into the base with two holes of 

suitable diameter corresponding to the position of the holes in the bottom of the box. 
Place the base at the desired location and attach it with suitable bonding material 
according to the substrate.

3. Insert the battery into the sensor and check correct location (the sensor functionality 

message is sent to the application when the battery are inserted).

4. Replace and snap the front cover. When closing, the handles have to be snapped to their 

original position. To ensure the degree of protection, tighten the grommet carefully.

* The glue must meet the optimal conditions for product placement (infl uence of tem-

perature, humidity ...)

** For example, a screw or screw of max. Ø 4 mm can be used as a suitable fastener mate-

rial, 13 mm (distance to the partition in the box) must be added to the required length 
for attachment to the substrate.

CleverFarm a.s.

Vídeňská 188/119d
619 00 Brno
www.cleverfarm.org
[email protected]

Reviews: