background image

97873C (Rev. H - 08/16)

ERO8C*C, *2C

PAGE 1

Installation/Care/Use Manual

Soft Sides

 Refrigerated Fountain with FLEXI-GUARD

®

To assure you install this model easily and correctly, PLEASE READ THESE 

SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK 

YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND 

OTHER APPLICABLE CODES. After installation, leave these instructions inside the 

fountain for future reference.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO 

WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY 

OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO 

A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE 

IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER 

MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE 

OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.

12

14

SEE FIG. 4

31

FIG. 2

FIG. 1

Installer

31

B

C

A

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED 

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE 

PULLING IT OUT HELPS TO 

RELEASE TUBE

A

B

C

NOTE: WATER FLOW

            DIRECTION 

BUILDING WATER

            INLET

    SERVICE STOP

(NOT FURNISHED)

1/4" O.D. TUBE

WATER INLET

TO COOLER

3/8" O.D. UNPLATED COP-

PER TUBE CONNECT

COLD WATER SUPPLY

Summary of Contents for Soft Sides ERO8C-C

Page 1: ...L FEEDBACK INTO A FOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM 12 14 SEE FIG 4 31 FIG 2 FIG 1 Installer 31 B C A SIMPLY...

Page 2: ...7873C Rev H 08 16 ERO8C C 2C FIG 3 LEGEND A 1 4 O D TUBE CONNECT CHILLER WATER OUTLET B 3 8 O D TUBE CONNECT CHILLER WATER INLET SHUT OFF VALVE BY OTHERS C 1 1 4 TRAP FURNISHED D ELECTRICAL INLET ERO8C ROUGH IN ...

Page 3: ... inserting 1 4 O D poly tubing provided 10 Remove elbow from end of p trap and attach it to drain tube Re attach elbow to p trap and cut waste tube to required length using plumbing hardware and trap as a guide 11 Connect power cord of sensor to solenoid valve by running it through the back panel and connecting it as shown in Fig 8 Connectors may be connected to either terminal on solenoid valve A...

Page 4: ...ver 1 8 diameter or a small diameter wire CAUTION Do not file or cut orifice materials 2 Stream Regulator If orifice is free of material deposits regulate water flow according to instructions on page 3 3 Sensor Control The sensor has a 2 second delay time If sensor fails to operate valve mechanism or operates erratically check the following a Ensure there are no obstructions within a 40 inch radiu...