background image

pushbutton

/

touch

sensor 

master unit - two wire

Product:

350A-1, 350A-2, 360A-1, 360A-2, 750A-1, 760A-1, 
550A-3, 550A-4, 560A-3, 560A-4 Two wire

Rating at 240V ac

• Incandescent   16A    • Compact Fluorescent   16A
• Resistive           16A    • Fluorescent   16A    • Time Delay 2min - 2h

The pushbutton/touch timer are part of the Elkay family of
switches, timers and detectors which save energy and increase
convenience in and around your home, garden or premises.

energy

sense

ene

rgy

style

energy

o

utdoor

pushbutton 

touch

sensor fitting and operating instructions

IMPORTANT NOTICE

All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE 17th Edition Wiring regulations BS7671:2008.

Call +44 (0) 1675 468222 or click www.elkay.co.uk

pushbutton 

touch

sensor

Pushbutton

Touch

LIVE IN

NEUTRAL

LIVE OUT

DIL 

switches

1.

2.

3.

4.

Battery

Lux level 

adjustment

Usage

The push button/touch timer are general purpose time controls.
Applications for suitable use include lighting and some heating
and ventilation controls. The timers can be used independently or
as a master unit when using slave trigger switches. One master
product only for each circuit being switched with additional slave
units at other positions in the circuit. 

WHEN USED WITH SOME LOW WATTAGE LIGHTING,
HEATING AND VENTILATION CIRCUITS PLEASE ENSURE A
CAPACITOR OF 2 MICROFARADS (MINIMUM) IS FITTED.
SUPPLIES OF SUITABLE ELKAY CAPACITORS CAN BE FOUND
AT YOUR STOCKIST (REF PFCC-1)

IMPORTANT

Please note that it is essential that the live in and

live out are identified prior to commencing the installation 
and steps 1 – 3 are followed precisely. No neutral is required on
this product (See diagram 1). Do not install the switch timer
with the mains power on as this can damage the product.

NOT SUITABLE FOR USE WITH CONTACTORS. DO NOT MEGGER
TEST OR INSULATION RESISTANCE TEST THIS PRODUCT.
REMOVE BEFORE TESTING OR TEST CIRCUIT PRIOR TO FITTING.

Your Elkay unit is compatible with a single gang, 25mm deep
British Standard accessory plate. Please ensure that the 
top and bottom lugs are removed from metal wall boxes 
prior to fitting. For 16mm boxes Elkay provide a spacer plate 
(product code220A-1) to take box depth to 25mm.

Slave fitting

When connecting with slaves use three core cable connecting the
live in, live out and trigger terminals as shown in Diagram 2. The
optional wire to the slaves only applies to the 350A and 550A
push button slave units and is ideal for retrofitting (See diagram 2). 

Please note that the trigger terminal is the third terminal. This
product requires a 24 hour power supply. The battery inside the
unit recharges when the light source or appliance is switched
OFF. Where the supply may be interrupted or isolated regularly
we must recommend our products from the three wire range.

Installation Steps

DO NOT APPLY MAINS UNTIL INSTRUCTED!

Step 1

- Ensure that the mains power to the circuit is switched off.

Place the previously identified Live In into the terminal marked L In
and the switched Live Out into the L Out terminal.

Step 2

- Switch the battery (switch 4) – you will notice a red LED

light flashing on the front of the unit- which will be flashing
rapidly. Whilst this is in action please select the desired timings
by selecting the appropriate time settings shown in diagram 3.

Diagram 1

Wiring diagram for a single sensor unit.

8526 PUSH BUT & TOUCH INSTRUCTIONSv3_Layout 1  25/02/2010  14:43  Page 1

Reviews: