Combination Refrigerated Drinking Fountain (Cooler) and Bottle Filling Station delivers chilled, clean potable drinking water. Top Bottle  

Filling section offer touchless activation to dispense water for bottles. While the bottom Water Cooler section, which houses the refrigeration 

and filtration systems, delivers a steady stream of water for direct drinking.

•  Electrical: 220-240 Vac, 50/60 Hz, (See Nameplate for Amperage),  

1 phase

•  Ambient Air Temperature: 50-89.6 °F (10-32 °C)
• 

Water Pressure: 20-105 psig (0.14-0.72 MPa)

• 

Maximum Water Temperature: 90 °F (32 °C)

• 

Sound Pressure level (A-weighted): < 70 dBA

•  Refrigerant: R290
•  Ingress Protection: IP20
• 

For Indoor Commercial Use only     

• 

Water Inlet: 3/8”O.D. unplated copper tube

• 

Waste Water Outlet: 1-1/4” O.D. tube

DANGER

 

– Indicates death or serious injury will result if proper precautions are not taken.

WARNING

 – Indicates death, serious injury or property damage can result if proper precautions are not taken.

CAUTION

 – Indicates some injury or property damage may result if proper precautions are not taken.

Definitions

Authorized Service Personnel

 – Factory trained personnel or personnel having working knowledge of electrical, plumbing and 

machine (appliance) maintenance procedures. Service personnel must have specialized training for flammable refrigerants.

Safety

DANGER

• 

Please read these instructions completely before starting the installation or performing any service. Failure to follow the instructions                                       

and safety precautions in this manual can result in serious injury or death.

•  After installation, keep these instructions in a safe location for future reference.
• 

Electric supply must be identical in voltage, cycle, and phase to that specified on nameplate.

• 

Electrical supply may require Ground Fault Circuit Interrupter (GFCI) protection. Consult specific application and local codes. 

• 

A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules. This is to 

allow electrical disconnection of the unit from electrical supply after installation.

WARNING

•  Keep clear of obstructing all ventilation openings in the appliance enclosure or in the structure for building-in.
•  Place in a well ventilated area to prevent accumulation of refrigerant.
• 

No open flame or sparks during service or repair.

• 

For use with clean, clear potable drinking water only. Do not use with water that is microbiologically unsafe or of unknown quality without 

adequate disinfection before the system.

•  Installation and connection to water and electrical mains must be in compliance with local and national laws. 
• 

All Installation and Service work must be performed by trained / authorized service personnel. 

Description

Ratings

Notice: 

Coolers that use flammable refrigerants, such as R-600a (isobutane), R-290 (propane) will be marked with a 

 

specific symbol that notifies the servicer of the presence of these refrigerants. A service provider should review this marking 

and follow all instructions from the original equipment manufacturer.

Installation & Use Manual

Original Instructions

Model: LZO8WSS2KWN Bottle Filling Station & Cooler

Summary of Contents for LZO8WSS2KWN

Page 1: ...structions and safety precautions in this manual can result in serious injury or death After installation keep these instructions in a safe location for future reference Electric supply must be identical in voltage cycle and phase to that specified on nameplate Electrical supply may require Ground Fault Circuit Interrupter GFCI protection Consult specific application and local codes A means for di...

Page 2: ...ide of tube and re flush before use 3 Install waste trap Remove the slip nut and gasket from the waste trap and install them on the cooler waste line making sure that the end of the waste line fits into the waste trap Assemble the slip nut and gasket to the waste trap and tighten securely IMPORTANT If it is necessary to cut the drain loosen the screw at the black rubber boot and remove tube check ...

Page 3: ...rted securely Add fixture support carrier if wall will not provide adequate support 4 Install wall mounting plate to wall using six 6 7 16 11mm oval mounting holes mounting bolts not included See Fig 2 Use appropriate fasteners for your wall type 5 Feed the modular C 13 end of International Power Cord and 3 8 water line through hole in tower basin gasket See Fig 4 6 Install gasket on bottom of bot...

Page 4: ...ply on and inspect for leaks Fix all leaks before continuing 15 Once unit has been inspected for leaks and any leaks found corrected connect plug end of International Cord Sets from the Cooler and Bottle Filler into electrical outlet Be sure to reinstall fuse to the circuit or switch the circuit breaker back to the ON position 16 Once power is applied to Bottle Filler the GREEN LED light should il...

Page 5: ...e count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count 3 When display shows UNIT TYPE push program button once the display will show current value Can be REFRIG or NON RFRG 4 Push button once to...

Page 6: ...ith press bars see Cooler Manual Water Valve Mechanism Adjustment Procedure 4 Cooler Sensor Range Adjustment The electronic sensor used in this cooler is factory pre set for a visual range of 36 inches 914 mm If actual range varies greatly from this or a different setting is desired follow the range adjustment procedure below Using a small tip screwdriver locate range adjustment screw through the ...

Page 7: ...side of the upper shroud Remove the access panel by removing the retaining screw To remove the bubbler loosen locknut from the underside of the bubbler and remove the tubing from the quick connect fitting see above When installing replacement bubbler and pedestal tighten nut only to hold parts snug in position while ensuring the locator in the basin is in the detent of the bubbler Do Not Overtight...

Page 8: ...C 1000003922 27416C 27413C See Filter Table 35826C 40608C 2000000621 1100000002 Description Hanger Bracket Basin Stainless Steel Compr Service Pak 230V 50Hz Polytube Cut To Length Assy Shroud Upper EZ Drier Kit Drain Replacement EZ BF Brckt Tube Ftg Clamp Kit Flexi Bubbler O Ring Nut Push Front EE Kit Cold Control Screws Kit Internal Wiring Pwr Cord Black and White Jumper Wires Kit Fan Motor Assy ...