ELK-319DG All Weather Door & Gate Sensor
Description
The ELK-319DG is a Supervised, Wireless Sensor uniquely
designed for outdoor use on swing gates or doors. The sensor
and magnet can be mounted using screws (included) or pipe
strap style clamps or plastic wire ties.
When activated the sensor transmits an open (trip) or close
(restore) signal to the panel. Additionally transmitted signals
include: tamper, hourly supervisory, and low battery (as
needed). The sensor is powered by two (2) replaceable 3VDC,
lithium coin-cell batteries.
This sensor is compatible with Elk’s 319MHz Receivers/Panels
as well as many other panels that operate on the 319.5MHz
Frequency and adhere to the ITI/Interlogix protocol.
Specifications
RF frequency: 319.5 MHz
Compatibility: ELK-319 Receivers/Panels & other panels
that operate on the 319.5MHz Freq. and
adhere to the ITI/Interlogix protocol
Battery type: Two (2) 3VDC lithium coin-cell
(Panasonic or Varta Model CR2032)
Operating
Temp Range: -40 to 140°F (-40 to 60°C)
Storage
Temp Range: -40 to 140°F (-40 to 60°C)
Relative
Humidity:
95% non-condensing
Dimensions Sensor: 3.39” L x 1.34” W x 0.79” D
Magnet: 3.0” L x 0.96” W x 0.8” D
Programming (Enrollment)
The following is a general guideline for programming (enrolling)
a sensor into the receiver or panel. For more extensive
instructions please refer to the receiver or panel instructions.
1. Place panel into the Program mode.
2. Proceed to the WIRELESS SETUP menu.
3. Select the appropriate zone/sensor location number.
4. When prompted by the panel to trip the sensor for learning:
• Remove sensor cover and remove battery pull tabs to power
up the sensor. Press and release the tamper plunger.
• The panel should acknowledge the sensor has been learned
by keypad display and/or audio alert (depending on the
panel). If enrollment fails try pressing and releasing the
tamper plunger a second time. In some cases it may be
necessary to remove and reinstall the batteries.
5. Repeat the above process for any additional wireless
sensors. Proceed to the zone programming to assign each
sensor’s zone definition.
6. Exit programming mode when finished.
Installation Guidelines and Mounting
• Sensor should be temporarily attached at the desired
location and successfully tested with the panel/receiver
prior to drilling any holes or permanently mounting.
• Mounting this sensor on metal can negatively affect the
transmitting range and magnet gap performance.
• Install the sensor within 100 ft. of the receiver or panel.
Use long screws (provided)
to attach the Magnet.
• Mount the sensor on the non-moving post or frame surface
and the magnet on the actual moving gate or door. If one
sensor is to be used for a double acting gate/door then
mount the sensor on the least used gate/door.
• Mount at least 5 inches above the floor to avoid damage.
• Align the magnet directly across from the top right edge of
the sensor.
NOTE: The gap between the sensor and magnet should
not exceed a maximum of 1”.
TM
Interlogix is a registered trademark belonging to United Technologies.
Mounting with Screws
Remove the sensor cover. Use long screws (provided) to attach
the sensor and the short screw (provided) to secure the cover.
Mounting with Pipe Straps or Plastic Ties
The Sensor and Magnet are also designed for mounting using
adjustable straps or black plastic ties. (purchase separately)
Use two (2) adjustable pipe straps or ties to
mount the sensor as shown.
Note: Make sure straps are tight to pre-
vent the sensor from sliding away from
the magnet.