ELK-319GB Wireless Glass Break Detector
Description
The ELK-319GB is a Supervised, Wireless Glass Break
Detector which provides alarm, tamper, and low battery signal
transmissions. The detector is powered by two (2) replaceable
3VDC lithium batteries and is compatible with Elk’s 319MHz
Receivers/Panels as well as many other panels that operate
on the 319.5MHz Frequency and adhere to the ITI/Interlogix
protocol.
Specifications
RF frequency: 319.5MHz
Battery type:
Two (2) 3VDC lithium battery
(Panasonic CR123 or equiv.)
Tamper Switch: Front Cover and Pry Off detect
Range:
20’ Ft (6m) Max. 4 sensitivity settings
Operating Temp: -14 to 122°F (-10 to 50°C)
Max. Humidity: 90% Relative Humidity non-condensing
Dimensions 3.9” x 2.75” x 1.5”
Programming (Enrollment)
The following is a general guideline for programming (enrolling)
a sensor into the receiver or panel. For more extensive
instructions please refer to the receiver or panel instructions.
1. Place the panel into the Program mode.
2. Proceed to the WIRELESS SETUP menu.
3. Select the appropriate zone/sensor location number.
4. When the panel prompts to trip the sensor do the following:
• Separate sensor from the mounting base
• Remove battery pull tabs (if present) to power the sensor
• The panel should acknowledge sensor has been learned
by a display on the keypad and/or audio alert (depending
on the panel). If enrollment does not succeed repeat the
process by removing and reinstalling the battery OR try
pressing and releasing the tamper plunger.
5. For additional sensors of this type repeat the above process.
Proceed to the zone programming to assign each sensor’s
zone definition.
IMPORTANT: Set the Zone Loop as “1”.
6. Exit the panel Program mode when finished.
Installation Guidelines
It is recommended that the unit be mounted at a height no lower
than 6 1/2’ (See Examples of Mounting).
• Maintain a distance of at least 4’ ft. away from any active
ultrasonic type of sensors or devices.
• All areas of glass to be monitored must be within a clear
line of sight of the unit. Distance from the unit to the most
remote point of monitored glass shall not exceed 20’ ft (6m).
• Do not mount outdoors
• Install sensor within 100 ft. of the receiver or panel.
• Do not mount on metal surfaces as this reduces range.
• Mounting surface must be solid with no vibration.
TM
Interlogix is a registered trademark belonging to United Technologies.
Sensitivity and Range Settings
The DIP Switches are used to select the Sensitivity. Default
setting is MAX. Sensitivity also directly affects the Range of
Detection as shown in the chart below.
SENSITIVITY
DETECT
RANGE
SW1-1
SW1-2
MAX
6M
OFF
OFF
MEDIUM
4M
OFF
ON
LOW
2.5M
ON
OFF
LOWEST
1.5M
ON
ON
LED Operation & Testing
In normal operation the Red LED lights solid for 5 seconds whenever
glass breakage is detected. When batteries are first installed a test
mode will be active for 5 minutes. During this time the microphone
detection range may be tested by clapping your hands or jingling a
set of keys. Test mode may be restarted for another 5 minutes by
removing and reinstalling the batteries.
SW1-1
SW1-2
RED LED
CONDITION
Slow Flash (once per second)
Test Mode is Active
Rapid Flash for approx. 2
seconds
Sound Detected
ON soiid for 5 seconds
Alarm (normal operation)
Back Housing
Mounting Holes(3)
Tamper Switch Hole
Battery Pull Tabs
Batteries (2)
Tamper Switch
Housing Front
DIP Switches
Cover Latch