ELK-319GB Wireless Glass Break Detector

Description

The ELK-319GB is a Supervised, Wireless Glass Break 

Detector which provides alarm, tamper, and low battery signal 

transmissions.  The detector is powered by two (2) replaceable 

3VDC lithium batteries and is compatible with Elk’s 319MHz 

Receivers/Panels as well as many other panels that operate 

on the 319.5MHz Frequency and adhere to the ITI/Interlogix 

protocol.

Specifications

RF frequency:  319.5MHz 

Battery type:  

Two (2) 3VDC lithium battery

   

(Panasonic CR123 or equiv.)

Tamper Switch:  Front Cover and Pry Off detect

Range: 

20’ Ft (6m) Max.   4 sensitivity settings

Operating Temp: -14 to 122°F (-10 to 50°C) 

Max. Humidity:   90% Relative Humidity non-condensing 

Dimensions      3.9” x 2.75” x 1.5”  

Programming (Enrollment)

The following is a general guideline for programming (enrolling) 

a sensor into the receiver or panel. For more extensive 

instructions please refer to the receiver or panel instructions. 
1.  Place the panel into the Program mode. 
2.  Proceed to the WIRELESS SETUP menu. 
3.  Select the appropriate zone/sensor location number. 
4.  When the panel prompts to trip the sensor do the following: 

•    Separate sensor from the mounting base
•    Remove battery pull tabs (if present) to power the sensor
•    The panel should acknowledge sensor has been learned 

by a display on the keypad and/or audio alert (depending 

on the panel).  If enrollment does not succeed repeat the 

process by removing and reinstalling the battery OR try 

pressing and releasing the tamper plunger.

5.  For additional sensors of this type repeat the above process.  

Proceed to the zone programming to assign each sensor’s 

zone definition.  

IMPORTANT: Set the Zone Loop as “1”.

6.  Exit the panel Program mode when finished. 

Installation Guidelines

It is recommended that the unit be mounted at a height no lower 

than 6 1/2’ (See Examples of Mounting).

•   Maintain a distance of at least 4’ ft. away from any active 

ultrasonic type of sensors or devices.

•   All areas of glass to be monitored must be within a clear 

line of sight of the unit.  Distance from the unit to the most 

remote point of monitored glass shall not exceed 20’ ft (6m).

•   Do not mount outdoors
•  Install sensor within 100 ft. of the receiver or panel.
•  Do not mount on metal surfaces as this reduces range. 
•  Mounting surface must be solid with no vibration. 

TM

  Interlogix is a registered trademark belonging to United Technologies.

Sensitivity and Range Settings

The DIP Switches are used to select the Sensitivity.  Default 

setting is MAX.  Sensitivity also directly affects the Range of 

Detection as shown in the chart below.

SENSITIVITY

DETECT 

RANGE

SW1-1

SW1-2

MAX

6M

OFF

OFF

MEDIUM

4M

OFF

ON

LOW

2.5M

ON

OFF

LOWEST

1.5M

ON

ON

LED Operation & Testing

In normal operation the Red LED lights solid for 5 seconds whenever 

glass breakage is detected.  When batteries are first installed a test 

mode will be active for 5 minutes.  During this time the microphone 

detection range may be tested by clapping your hands or jingling a 

set of keys.  Test mode may be restarted for another 5 minutes by 

removing and reinstalling the batteries.

SW1-1

SW1-2

RED LED

CONDITION

Slow Flash (once per second)

Test Mode is Active

Rapid Flash for approx. 2 

seconds

Sound Detected

ON soiid for 5 seconds

Alarm (normal operation)

 

Back Housing
Mounting Holes(3)
Tamper Switch Hole
Battery Pull Tabs
Batteries (2)
Tamper Switch
Housing Front
DIP Switches
Cover Latch