25
SWITCHING OFF THE HEATER
To switch off the heater, press the
button
. The display will start counting down the time of 30 seconds
during which the heater will work as a fan, then it switches to standby mode. The current room temperature
remains on the display. To switch off the device completely, disconnect the power cord from the socket!
Warning:
During the first use and heating, there is a firing of the heating element. It is just a temporary
phenomenon that stops after a few minutes. Ventilate the room and continue heating.
OVERHEATING PROTECTION
The heater has a built-in fuse that automatically switches off the heater when overheated (at 51 °C). In this case,
unplug the heater and let it cool down. Check that the air inlet and outlet are not blocked. After cooling down,
switch on the heater again. If the heater still does not work, contact an authorized service center.
STORAGE
•
Before storing the heater, unplug it and let it cool down!
•
If you will not be using the heater for a long time, store it in its original packaging or bag. It will be protected
from the concentration of dust and dirt.
•
The product must be stored in a dry place, out of direct sunlight.
•
It is expressly forbidden to store the device in humid or wet areas.
This function can be activated in all heating modes except fan mode.
Press the button
to turn detection on or off. When the detection is switched on, the indicator
flashes.
Temperature detection starts 1 minute after switching on (temperature detection checkpoint is created). If the
heater electronic control detect an open window and a sharp drop in the ambient temperature of 8 °C within 10
minutes - (one round, temperature detection once every 5 minutes), the heater automatically stops heating.
Description of the function/time intervals of one detection round:
•
0:00 - Open window detection activation
•
1:00 - Starting temperature detection, start of the round. A temperature detection start checkpoint is created.
•
6:00 - Temperature detection checkpoint 1 - temperature fast down detection check point
- Temperature detection check point 1 reduce from Temperature detection starting checkpoint is ≤ 8 °C - the
heater continues to heat, open window detection remains active.
- Temperature detection check point 1 reduce from Temperature detection starting checkpoint is > 8°C - the
heater switches off the heating and turns into standby mode, open window detection is switched off - see
Notes
.
- The measured temperature is higher than Temperature detection start checkpoint - the heater continues to
heat, open window detection remains active. (Maximum detection temperature is 51 °C - Overheat protection)
•
11:00 - Temperature detection checkpoint 2 - temperature slow down detection check point
- The temperature measured at this point is the end of the first round and the beginning of the second round of
measurement. For 10 minutes as one round, the temperature is measured every 5 minutes. At this point, the
temperature detection method is the same as in detection point no. 1.
Notes on Open window detection:
If the heater detects a drop in temperature and switches off the heating, the alarm is activated for 5 seconds,
OF is on and the entire display flashes. The heater works for another 30 s in fan mode and then switches off
to standby mode. To restore the function to the original mode, press
before switching off. When the Open
window detection mode is restored, a new round of detection will start.
EN
OPEN WINDOW DETECTION
CANCELING THE WEEKLY PROGRAM
1.
Press
during program setting.
2.
If the setting has already been completed, press
first and then
.
If the Weekly program has been switched on in Temperature setting mode, after canceling it, the heater will return
to Temperature setting mode. (If the Weekly program has been switched on in LOW or HIGH heating modes, after
canceling it, the heater will continue in the selected LOW / HIGH heating mode).
CANCELING THE TEMPERATURE SETTING MODE
1.
Press during program setting.
2.
If the setting has already been completed, press
first and then
.
When the mode is canceled, the heater switches to fan mode.
3.
Press
, the heater switches to heating mode.
Summary of Contents for EWH 201
Page 2: ...2...