4.1.2. Operational pressure of measured liquid 

 
The standard flow-sensor versions have the following pressure ratings: 
 

Sensor size 

Pressure rating 

DN 15 to DN 50 

PN 40 (4,0 MPa) 

DN 65 to DN 200 

PN 16 (1,6 MPa) 

DN 250 to DN 800 

PN 10 (1,0 MPa) 

 
 
Relationship between operational pressure and temperature of the measured liquid. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

4.1.3. 

Material of electrodes 

 

Measurement  electrodes  are  made  of  stainless  steel  1.4571  (316Ti).  Some  special  applications  require 

use of higher-quality and more resilient materials. We provide electrodes made of Hastelloy C276, Tantalum, 
Titanium and Platinum-Rhodium (PtRh10). 

 

4.1.4. Selection of sensor lining 

 

The  sensors  are  produced  with  linings  of  different  materials.  Selection  of  lining  material  depends  on 
properties of measured liquid. 
 

Soft rubber, low aggressive liquids, -35

o

to 80ºC, higher content of abrasive particles 

 

 

Hard rubber, low aggressive liquids, +5 

to 80ºC 

 
Special rubber for potable water, +5 to 8

0ºC 

 
Teflon PTFE, aggressive liquids with operating temperature 

–20 to +110ºC, on request –35 to +150ºC 

 
E-CTFE, operating temperature -20 to +11

0ºC, for dimensions over DN300, on request –35 to +130ºC 

 
 

Summary of Contents for FLONET FN50 Series

Page 1: ...bly and Service Manual Page 1 of 32 Electromagnetic flowmeter FLONET FN50xx 1 ELIS PLZEN a s Lucni 425 15 301 00 Plzen Czech Republic Phone 420 377 517 711 fax 420 377 517 722 Es90716K Electromagnetic...

Page 2: ...PLZE a s Design Assembly and Service Manual Page 2 of 32 Electromagnetic flowmeter FLONET FN50xx 1 ELIS PLZEN a s Lucni 425 15 301 00 Plzen Czech Republic Phone 420 377 517 711 fax 420 377 517 722 Es9...

Page 3: ...heat meters 13 4 1 6 Dimensions of flanged sensor IS0 Mxx for heat meters 14 4 1 7 Dimensions of flangeless sensor ISX 1xx 15 4 1 8 Dimensions of flanged sensor ISX 1xx 16 4 1 9 Technical data of sens...

Page 4: ...meter has only one galvanic isolated passive pulse output OUT1 The basic parameters can be set during activation process using special USB channel and sw FLOSET it isn t standard in a delivery 2 MEASU...

Page 5: ...meter sensor is with different type of lining hard rubber soft rubber and special hard rubber for drinking water PTFE or E CTFE with electrodes from different material and in flanged or wafer flangele...

Page 6: ...ic flowmeter FLONET FN50xx 1 ELIS PLZEN a s Lucni 425 15 301 00 Plzen Czech Republic Phone 420 377 517 711 fax 420 377 517 722 Es90716K Example of flowmeter assembly in the remote design version Dimen...

Page 7: ...lzen Czech Republic Phone 420 377 517 711 fax 420 377 517 722 Es90716K 3 3 Protection of meters against unprofessional handling The meter shall be provided with an assembly seals after installation wh...

Page 8: ...r flow velocities the measurement accuracy is worse while at higher flow velocities the turbulences at contact edges may cause undesirable interference Minimum and maximum flow rates for various senso...

Page 9: ...m3 h Min flow qi m3 h Ratio qp pi 15 6 5 3 0 0163 200 20 12 6 0 0300 25 18 9 0 0450 32 30 15 0 0750 40 45 23 0 1125 50 72 36 0 1800 65 150 75 0 3750 80 180 90 0 4500 100 280 140 0 70 125 430 215 1 08...

Page 10: ...420 377 517 711 fax 420 377 517 722 Es90716K The basic parameters of flow meters are designed in compliance of standard ISO 4064 OIML R 49 Below is issued ratio of following flow rates Q4 1 25 Q2 1 6...

Page 11: ...0 0168 0 024 25 18 14 4 0 1152 0 072 0 0252 0 036 32 30 24 0 192 0 12 0 042 0 06 40 45 36 0 288 0 18 0 063 0 09 50 72 57 6 0 4608 0 288 0 1008 0 144 65 120 96 0 768 0 48 0 168 0 24 80 180 144 1 152 0...

Page 12: ...surement electrodes are made of stainless steel 1 4571 316Ti Some special applications require use of higher quality and more resilient materials We provide electrodes made of Hastelloy C276 Tantalum...

Page 13: ...s sensor ISX Mxx for heat meters L D A D N M6 Flangeless sensor dimensions for various rated diameters DN DN D A L Hmotnost kg 25 72 165 104 2 PN40 32 82 175 104 2 40 92 186 104 2 50 107 199 104 3 65...

Page 14: ...6 2 5 25 115 72 187 200 96 3 PN40 32 140 82 206 200 96 4 40 150 92 216 200 96 4 50 165 107 230 200 96 6 65 185 127 251 200 96 9 80 200 142 267 200 96 14 PN16 100 220 162 287 250 96 16 125 250 192 317...

Page 15: ...s of flangeless sensor ISX 1xx L A D DN Dimensions of flangeless sensor according to DN DN D A L Hmotnost kg 25 72 158 104 2 PN40 32 82 168 104 2 40 92 179 104 2 50 107 192 104 3 65 127 212 104 3 80 1...

Page 16: ...66 3 25 115 72 180 200 96 3 PN40 32 140 82 199 200 96 4 40 150 92 209 200 96 4 50 165 107 223 200 96 6 65 185 127 244 200 96 9 80 200 142 260 200 96 14 PN16 100 220 162 280 250 96 16 125 250 192 310...

Page 17: ...sensor Flangeless Flanged Earthing Earthing electrode Flow rate of measured liquid 0 05 m s to 10 m s range 1 200 Temperature of measured liquid 110 o C Up to 150 C on a request based on lining type a...

Page 18: ...le bushing fitted at the angle bracket the connecting cable connects electronic unit and junction box of sensor 4 2 1 Electronic unit specifications Power source 85 to 305 VAC 47 440 Hz Power consumpt...

Page 19: ...an 3 from that of the sensor If more than one flow disturbing element such as pipe bend or fitting are located near the sensor the required length of straight piping section on the sensor side concern...

Page 20: ...mounted in a vertical position In the cases where the sensor is mounted in a vertical position the flow direction shall always be upwards Risk of liquid aeration Permanent flooding of sensor To ensur...

Page 21: ...le solution in the cases where to dismantle the flow sensor from the piping liquid from a very long piping section would have to be discharged 5 2 Sensor earthing The correct meter function requires t...

Page 22: ...th no protruding edges The arrow on the sensor body indicates the required fluid flow direction positive flow direction Do not expose the electronic unit box to direct sunlight in the cases of outdoor...

Page 23: ...lding shall be connected to the earth potential on the side of the plant control system Upon connecting the conductors to the terminals tighten the bolts holding the electronic box cover and check the...

Page 24: ...an be performed via special serial communication line USB ELIS PLZE a s delivers as a producer 7 OPTIONAL SETTINGS The electromagnetic flowmeter is standardly set at the factory If the customer needs...

Page 25: ...e 15 1 6 0 1 20 3 0 1 25 5 0 1 32 8 33 0 1 40 12 5 1 50 20 1 65 33 33 1 80 50 1 100 77 77 1 125 119 44 10 150 180 55 10 200 319 4 10 250 500 10 300 700 10 350 972 10 400 1250 100 500 2000 100 600 2778...

Page 26: ...circuit board after removing the cover and cover plates electronics It is necessary to connect PC with diagnostic software and in the section ERRORS to check which error is signalized Code error Desc...

Page 27: ...delivery to the customer enclosed to the flowmeter FLONET FN50XX shall be a delivery note operation and maintenance manual and a statement on the product compliance with the respective standards 11 W...

Page 28: ...of sensor DN max flow rate Qmax m3 h inch max flow rate Qmax US G h 15 6 5 1 2 1717 0 1 20 12 3 4 3170 0 2 25 18 1 4755 0 3 32 30 1 1 4 7920 0 4 40 45 1 1 2 11887 0 5 50 72 2 19019 0 6 65 120 2 1 2 3...

Page 29: ...er 0 to 80 C DN20 to DN800 1 teflon PTFE 20 to 150 C DN15 to DN250 2 E CTFE 20 to 130 C DN300 to DN800 3 non standard X Sensor protection standard IP 65 1 Grounding sensor to piping 1 grounding electr...

Page 30: ...ation acc to EN1434 accuracy 0 5 without cal certificate 4 above standard calibration acc to EN1434 accuracy 0 5 with cal certificate 5 standard calibration acc to ISO 4064 without cal certificate 6 s...

Page 31: ...LZE a s Design Assembly and Service Manual Page 31 of 32 Electromagnetic flowmeter FLONET FN50xx 1 ELIS PLZEN a s Lucni 425 15 301 00 Plzen Czech Republic Phone 420 377 517 711 fax 420 377 517 722 Es9...

Page 32: ...er FLONET FN50xx 1 ELIS PLZEN a s Lucni 425 15 301 00 Plzen Czech Republic Phone 420 377 517 711 fax 420 377 517 722 Es90716K Manufacturer s address ELIS PLZE a s Lu n 15 301 00 Plze Czech Republic Te...

Reviews: