The ELGO Electric 54 AG Series is a high-performance electric system with advanced features. Make sure to download the free manual from our website to learn how to make the most of this innovative product. manualshive.com.
Z54 & Z56 Series
Z54-56-000-E_41-99.doc Doku Art. Nr. 799000101
Programmable Position Indicators
Series 54:
For use with Encoders
Series 56:
For use with MX magnetic scale
Page 1: ...Z54 Z56 Series Z54 56 000 E_41 99 doc Doku Art Nr 799000101 Programmable Position Indicators Series 54 For use with Encoders Series 56 For use with MX magnetic scale...
Page 2: ...dit datum Offset 6 Edit Datum 1 bit 6 Edit Flexible Multiplier 6 Changing Display Value 7 Counter Configuration 7 Configuration Register 8 Direction of Count 9 Decimal Places 9 Inch Metric Switching 9...
Page 3: ...xternal inputs The Range available is as follows Series 54 single axis indicator available in LED or LCD display formats Suitable for encoder feedback Series 56 single axis indicator available in LED...
Page 4: ...s with a fixed offset that can be readily toggled Incremental Absolute operation When pressed on its own switches between absolute and incremental operation In many applications dimensions are given o...
Page 5: ...fset It is only possible for the operator to edit the Datum and Datum Offset if the editing feature is unlocked in the configuration register XXX0X NB The Datum and Offset values incorporate any decim...
Page 6: ...e is not possible when this feature is selected Press both buttons for three seconds any value may now be set in the normal way subtracts one bit press adds one bit press to the displayed value Edit F...
Page 7: ...ment the digit between 0 and 9 stores the value to the internal RAM and returns the indicator to operating mode Counter Configuration F Press buttons for three seconds the Configuration mode is entere...
Page 8: ...X X X X X Series 54 Encoder feedback only Series 56 Scale feedback only Display extinguish 0 No auto extinguish and no clamp extinguish 1 Total power off on with F button 2 Total power off after 5 min...
Page 9: ...ction Press F to store value to RAM and return to Config Press all four buttons again for three seconds to return indicator to operating mode General Technical Information Indicators Maximum counting...
Page 10: ...20 60 Maximum speed of travel 5m sec Cable length 3m standard up to 25m available Operating temperature 5 to 45 deg C Sealing IP66 Magnetic Tape MB20 50 xx x Resolution 0 1mm Operating temperature 5 t...
Page 11: ...tion ST3 AC input Pin 1 L Pin 2 N Pin 3 E ST2 Encoder Pin 1 0 volts Pin 2 24 volts dc Pin 3 Channel A Pin 4 Channel B Pin 5 Screen ST3 Series 56 AG BU1 ST3 AC input Pin 1 L Pin 2 N Pin 3 E BU1 MX magn...
Page 12: ...ns Outline Dimensions Side View 92mm 66mm 72 mm 96mm 62mm 68mm mm 107mm 76 95mm 90mm M6 60mm 30mm Panel Mounting Series 54 and 56 AG Enclosure Mounting Series 54 and 56 NG20 0 Power Supply 80mm 45mm D...
Page 13: ...For 56 series indicators to operate on 110 230 v ac use the 024 version and order a separate NG20 0 power supply AG versions always include NG20 0 mounted inside the enclosure 600 For Version 230 or 1...
Page 14: ...24 V DC 115 115VAC in 54 only 230 230VAC in 54 only Construction 000 standard 001 1 st special version etc Special Features EE External input AG Free standing Housing RS232 Serial port in 54 only M h...
Page 15: ...ly strive for improving our products therefore we keep all rights reserved for any technical modifications without any notice ELGO Electric does not assume any liability for possible errors or mistake...