4
Explosion Safety Parameters
37
4 Explosion Safety Parameters
DIN digital inputs:
(terminals DI1, GND, DI2, GND, DI3, GND, DI4, GND)
1/
Uo = 6.5V
Io = 2mA
Po = 3mW
IIB
IIA
Co
20
F
100
F
Lo
10mH
100mH
Ui = 5,5 V
Ii = 1 mA
Pi = 1 mW
Ci = 0, Li = 0
1/
ELCOR - 3 inputs only: DI1, GND, DI2, GND, DI3, GND
DOUT digital outputs:
(terminals U0+, GND0, DO1, DO2, DO3, DO4)
2/
Ui = 15V
Ii = 0.3A
Pi = 0.5W
Ci = 3.3uF
Li = 0
2/
ELCOR - 2 inputs only: U0+, GND0, DO1, DO2
IB0 and IB1 internal buses:
(terminals GND, U+, D-, D+)
3/
Uo = 6.5V
Io = 2.2A
Po = 1.1W
IIB
IIA
Co
24
F
50
F
Lo
4/
1uH
1uH
3/
ELCOR - IB0 only
4/
inductive concentration, max. 100m cable can be connected
KP 100 060 - Indexer interface:
(SLOT 0 TERMINALS: GND, U+, TXD, RXD, UB)
5/
Uo = 6.5V
Io = 2.2A
Po = 1.1W
Summary of Contents for DATCOM
Page 38: ...3 Technical Parameters 36 ...
Page 50: ...5 Installation and Commissioning 48 Fig 7 Examples of data plates ...
Page 83: ...5 Installation and Commissioning 81 Fig 37 Communication via RS232 RS485 using B RS module ...
Page 115: ...7 Technical Description of the Device 113 Fig 57 Functional diagram of ELCOR ...
Page 116: ...7 Technical Description of the Device 114 Fig 58 Functional diagram of ELCORplus ...
Page 122: ...7 Technical Description of the Device 120 Fig 61 Modem replacement ...
Page 159: ...10 Communication with the Device 157 packet ...
Page 174: ...12 Accessories 172 Fig 78 ELCORplus example of use of external modules ...
Page 213: ...Appendix 3 Compass Data Export 211 Preview of generated document ...
Page 215: ...Appendix 3 Compass Data Export 213 3 Export to XLS 4 Export to TXT DOC ...
Page 216: ...Appendix 3 Compass Data Export 214 ...
Page 217: ...Appendix 3 Compass Data Export 215 5 Export of graph ...