W14 Q1 Q1 max. limit
43
(1
st
channel)
W15 Qb1 Qb1 min. limit
44
Flow rate at base conditions user limits exceeded (1
st
channel)
W16 Qb1 Qb1 max. limit
45
W17
- not used -
W18
- not used -
W19 P2 P2 min. limit
50
Pressure user limits exceeded (2nd channel)
W20 P2 P2 max. limit
51
W21 T2 T2 min. limit
55
Temperature user limits exceeded (2nd channel)
W22 T2 T2 max. limit
56
W23
- not used -
W24
- not used -
W25
- not used -
W26
- not used -
W27
- not used -
W28
- not used -
W29 EEPROM m.bat
18
Memory error of the modem battery
W30 m.battery voltage
12
Modem battery voltage low
W31 communication error
28
Communication error
W32 user cover
29
Housing cover opened
W33 ext.power supply of modem
61
External power supply to the modem has failed
W34 metrol.switch
62
Metrological switch is ON
W35 user switch
63
Service switch is ON
W36 volume dif.
47
Volume limit has been exceeded when comparing volume
counters
W37 metrolog. cover
60
Cover of metrological part of the device was opened
W38 RTC setting
58
The system time has been set
W39 Primary volume setting
59
The primary volume has been set
M0 no configuration
30
The device is in Not configured state
M1 maintanance
31
The device is switched to Maintenance state
Table 15
List of events - error messages (Wrnr indication)
6.9.6 Status Word of the Device
The current status of the device is stored in the 64-bit status word of the device. Each of the
monitored status (eg temperature error, pressure error, battery status, etc.) is assigned a fixed bit
in the status word. The state of each bit indicates whether the status occurred or not.
i
If any monitored bit changed, the entire status word is stored in the status archive
with a time stamp.
The status word of the device is also stored in the data, daily and monthly archives. These
records store information about whether the bit has reached the active state during the archiving
Summary of Contents for DATCOM
Page 38: ...3 Technical Parameters 36 ...
Page 50: ...5 Installation and Commissioning 48 Fig 7 Examples of data plates ...
Page 83: ...5 Installation and Commissioning 81 Fig 37 Communication via RS232 RS485 using B RS module ...
Page 115: ...7 Technical Description of the Device 113 Fig 57 Functional diagram of ELCOR ...
Page 116: ...7 Technical Description of the Device 114 Fig 58 Functional diagram of ELCORplus ...
Page 122: ...7 Technical Description of the Device 120 Fig 61 Modem replacement ...
Page 159: ...10 Communication with the Device 157 packet ...
Page 174: ...12 Accessories 172 Fig 78 ELCORplus example of use of external modules ...
Page 213: ...Appendix 3 Compass Data Export 211 Preview of generated document ...
Page 215: ...Appendix 3 Compass Data Export 213 3 Export to XLS 4 Export to TXT DOC ...
Page 216: ...Appendix 3 Compass Data Export 214 ...
Page 217: ...Appendix 3 Compass Data Export 215 5 Export of graph ...