6
Operating the Device
105
E12
- not used -
E13 battery disconnected
19
Battery is disconnected
E14 P1 under limit
32
Pressure range exceeded (1st channel)
E15 P1 above limit
33
E16 P1 error
36
Pressure transducer error
E17 T1 under limit
37
Temperature range exceeded (1st channel)
E18 T1 T1 above limit
38
E19 T1 error
41
Temperature transducer error
E20 P2 under limit
48
Pressure range exceeded (2nd channel)
E21 P2 above limit
49
E22 P2 error
52
Pressure transducer error
E23 T2 under limit
53
Temperature range exceeded (2st channel)
E24 T2 T2 above limit
54
E25 T2 error
57
Temperature transducer error
E26 time synch
4
RTC synchronization error, adjustment by > 2 h was
required.
E27 mod.bat.capacity
15
The modem battery is discharged
E28 encoder error
20
Encoder error (SCR or NAMUR)
E29 CRC metrolog.
22
CRC error of metrological part of the FW
E30 CRC tables
23
CRC error in password or encryption key table
E31 FRAM error
26
FRAM memory error
E32 FLASH error
27
FLASH memory error
E33 bar sensor error
46
Integrated barometric transducer error
Table 14 List of events - error messages (Err indication)
Displayed Message
bit
Description
W0 transd. warning
11
Warning alert on one of connected transducers (internal
modules SCR, NAMUR, EXT1, SRM or other). Details can
be found by reading the parameters of the corrector.
W1
- not used -
W2 battery
13
Memory error in battery pack.
W3 overcurrent
14
Current overload occurred
W4
- not used -
W5 network failure
16
Mains power supply failure
W6
21
- not used -
W7 tamper contact 1
24
Tamper contact 1 active.
W8 tamper contact 2
25
Tamper contact 2 active.
W9 P1 min. limit
34
Pressure user limits exceeded (1
st
channel)
W10 P1 max. limit
35
W11 T1 T1 min. limit
39
Temperature user limits exceeded (1
st
channel)
W12 T1 T1 max. limit
40
W13 Q1 Q1 min. limit
42
Flow rate at measurement conditions user limits exceeded
Summary of Contents for DATCOM
Page 38: ...3 Technical Parameters 36 ...
Page 50: ...5 Installation and Commissioning 48 Fig 7 Examples of data plates ...
Page 83: ...5 Installation and Commissioning 81 Fig 37 Communication via RS232 RS485 using B RS module ...
Page 115: ...7 Technical Description of the Device 113 Fig 57 Functional diagram of ELCOR ...
Page 116: ...7 Technical Description of the Device 114 Fig 58 Functional diagram of ELCORplus ...
Page 122: ...7 Technical Description of the Device 120 Fig 61 Modem replacement ...
Page 159: ...10 Communication with the Device 157 packet ...
Page 174: ...12 Accessories 172 Fig 78 ELCORplus example of use of external modules ...
Page 213: ...Appendix 3 Compass Data Export 211 Preview of generated document ...
Page 215: ...Appendix 3 Compass Data Export 213 3 Export to XLS 4 Export to TXT DOC ...
Page 216: ...Appendix 3 Compass Data Export 214 ...
Page 217: ...Appendix 3 Compass Data Export 215 5 Export of graph ...