Sorensen DCS Series 3kW Supplies
Installation
2.5.2
AC Input Connector Assembly
Each unit is shipped with a connector and contacts which mate with the chassis-mounted AC
connector located on the rear panel. See
Figure 2-1 AC Connector and Contacts
Parts Supplied
•
One (1) connector (Part number MI-6432-672)
•
Five (5) contacts (Part number MC-3508-211)
Additional Parts Required
•
8 to 12 AWG wiring: three (3) wires for single phase inputs or four (4) wires for three
phase inputs. The neutral CONNECTOR wire of three-phase four (4) wire systems is not
required.
Figure 2-1 AC Connector and Contacts
Wire Preparation
1. Trim outer wire jacket 2". (Necessary for strain relief. See
2. Strip 0.300" at the end of the insulated AC input wire.
3. Crimp the stripped wire into the contact as indicated in
connection.
4. Crimp the contact around the wire insulation as indicated in
Figure 2-2 Wire Preparation
Operation Manual
2-5