www.elfinx.com
System Operation
Electronic / Air Compressor Lock Interchange
Press for 5 seconds, the siren sounds and lights flash. After that, the siren will stop chirping,
indicating that the interchange process has been completed successfully.
•
The default setting is electronic lock. The lock time is 0.8 seconds.
•
Air compressor lock time is 3.5 seconds.
10
Remote Control Code Cancellation and Installation
The security code stored in the remote and the main unit can be changed following the procedures
listed below:
Remote Control Code Cancellation
When in disarming mode, open a door and keep the door opened, then apply and keep on the brake.
Turn the ignition key from OFF to ON position 5 times. After the operation, the LED light turns off
and 1 long chirp sounds to indicate that the security code is cleared from the system.
Remote Control Code Installation
When in disarming mode, open a door and keep the door opened, then apply and keep on the brake.
Turn the ignition key from OFF to ON position 3 times. Then, 1 chirp sounds and the LED lights up
once. Press the button twice within 5 seconds. Two chirp sounds and the LED light turns off to
indicate a new security code is stored.
NOTE:
This system is designed to store only 2 different security codes at any given time.
11
Wire Connection Diagram
See wiring diagram
12
System Installation Guide
Main Unit Installation
The main unit is placed under the vehicle control panel. After fixing the main unit in a suitable place,
start connecting all the wiring according to the Wire Connection Diagram. Before putting back all the
OEM parts, simply test the system functions first.
Shock Sensor Installation
Install the shock sensor after
fixing the main unit. It is recommended to place the shock sensor near
the doors for easy detection of any intrusions. To adjust the sensitivity of the shock sensor, simply
use a screw to turn the knob on the shock sensor, turning right to set a higher sensitivity or vice verse.
Then test the sensitivity by triggering the shock sensor.