background image

 

 
Element P303BT User Guide I Page 53 of 53  

        

 

 
 

6.3

 

Appendix 3: Digit Barcodes 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for P303BT

Page 1: ...Element P303BT User Guide I Page 1 of 53 P303BT Scanner User Manual Rev 1 01 ...

Page 2: ... Dongle Settings 8 2 2 1 Cradle Factory Defaults 8 2 2 2 Baud Rate 8 2 2 3 Data Bit Parity Check Stop Bit 9 2 2 4 Cradle Country Keyboard Types 10 2 2 5 USB Interface 11 2 2 6 USB COM Port Emulation 11 2 2 7 Transmission rate 12 2 2 8 Transmission Mode 12 2 2 9 Synchronous transfer mode 12 2 2 10 Asynchronous transfer mode 12 2 2 11 Mass storage mode 12 3 General Configuration 14 3 1 Trigger Mode ...

Page 3: ... 5 4 EAN 13 26 5 5 UPC E 28 5 6 UPC A 32 5 7 Interleaved 2 Of 5 34 5 8 Matrix 2 Of 5 35 5 9 Industrial 2 Of 5 36 5 10 Code 39 37 5 11 Coda Bar 39 5 12 Code 93 40 5 13 GS1 128 41 5 14 Code 11 42 5 15 PDF 417 43 5 16 QR Code 44 5 17 Data Matrix 45 5 18 Maxi code 45 5 19 Aztec 46 6 Appendix 48 6 1 Appendix 1 AIM ID Table 48 6 2 Appendix 2 ASCII Table 49 6 3 Appendix 3 Digit Barcodes 53 ...

Page 4: ...and decoding accuracy Barcodes rotated at any angle can still be read with ease When scanning a barcode simply center the aiming beam or pattern projected by the Element 2D Barcode Reader over the barcode 1 3 Factory Defaults Scanning the following barcode can restore the engine to the factory defaults Note Use this feature with discretion Restore All Factory Defaults 1 4 Firmware Version Number S...

Page 5: ...etooth devices STEP3 Select the scanner name named after 12 SN characters on your device the scanner will work as a keyboard 2 1 3 Bluetooth serial port STEP1 Scan the barcode below to start a new connection The scanner will be discoverable in 120s Bluetooth serial port STEP2 Set your personal laptop or tablet so it searches for other Bluetooth devices STEP3 Select the scanner name named after 12 ...

Page 6: ...Element P303BT User Guide I Page 6 of 53 US default Belgian Finnish_Swedish French German Italian Swiss_German British Danish Novwegian Spanish ...

Page 7: ...Conversion Default Convert All To Upper Case Convert All To Lower Case 2 1 6 Input Method When a Bluetooth terminal connect with scanner its virtual keyboard will disappear at once You may need to scan the barcodes below to switch input language into English Switch Input Method Windows Android Switch Input Method iOS Popup Hide Virtual Keyboard iOS ...

Page 8: ...f 2 2 Bluetooth Cradle Dongle Settings Connect a scanner to Bluetooth cradle or dongle at first and then you can configure the cradle dongle 2 2 1 Cradle Factory Defaults Scan the barcode below can restore the cradle to factory defaults Restore Cradle Factory Defaults 2 2 2 Baud Rate Baud rate is the number of bits of data transmitted per second Set the baud rate to match the Host requirements ...

Page 9: ...f 53 2400 4800 9600 19200 38400 57600 115200 default 2 2 3 Data Bit Parity Check Stop Bit None Parity 7 Data Bits 1 Stop Bit None Parity 8 Data Bits 1 Stop Bit default Even Parity 8 Data Bits 1 Stop Bit None Parity 7 Data Bits 2 Stop Bits ...

Page 10: ...its 1 Stop Bit Odd Parity 8 Data Bits 1 Stop Bit Odd Parity 7 Data Bits 2 Stop Bit 2 2 4 Cradle Country Keyboard Types Keyboard layout varies from country to country American keyboard is default you can switch the Cradle Dongle s keyboard types by scanning the follow barcode USA default Belgian Finnish_Swedish French German Italian ...

Page 11: ... will be simulated as keyboard input The Hostreceives keystrokes on the virtual keyboard It works on a Plug and Play basis and no driver is required USB HID default 2 2 6 USB COM Port Emulation When you connect cradle to the Host via a USB connection the USB COM Port Emulation feature allows the Host to receive data in the way as a serial port does A driver is required for this feature visit the o...

Page 12: ... switch the transmission rate SX060F0C1 SX060F0C5 SX060F0C15 SX060F0C8 default 2 2 8 Transmission Mode 2 2 9 Synchronous Transfer mode Note Data transmit when Bluetooth connected drop when disconnected 2 2 10 Asynchronous Transfer mode Note Data is stored when Bluetooth disconnected and will upload automatically when reconnect 2 2 11 Mass Storage mode ...

Page 13: ...Element P303BT User Guide I Page 13 of 53 Note Data is always stored Upload all stored data Count total amount of uploaded data Clear stored data ...

Page 14: ...ial trigger command When in manual trigger mode the scanner scans until a barcode is read or until the hardware trigger is released When in serial mode the scanner scans until a barcode has been read or until the deactivate command is sent Manual Trigger Mode Normal Default 3 2 Presentation Mode This set the scanner to work in presentation mode Presentation Mode Normal Presentation Mode Continue S...

Page 15: ... the follow barcode can configure the Auto sense if Auto sense enable then putting barcode reader on the Cradle is Presentation mode and taking it off is Trigger mode Enable Disable default 3 4 Inverse color OFF Default Only Inverse ON Inverse And Normal Both ON ...

Page 16: ... ON default Illumination OFF Manual Trigger Mode Illumination setting for 22XX 24XX 26XX BLE series Illumination Level 4 Default Illumination Level 3 Illumination Level 2 Illumination Level 3 Manual Trigger Mode Illumination setting for 51XX 52XX BLE series Level 1 Level 2 ...

Page 17: ...Element P303BT User Guide I Page 17 of 53 Level 3 Level 4 default Presentation Mode Illumination setting Illumination Level 4 Default Illumination Level 3 Illumination Level 2 Illumination Level 3 ...

Page 18: ...Element P303BT User Guide I Page 18 of 53 3 6 Good Read Beeper ON Default OFF 3 7 Good Read Beeper Volume Low Middle High Default ...

Page 19: ...Element P303BT User Guide I Page 19 of 53 3 8 Good Read Delay No Delay Default Delay 500 MS Delay 1000 MS 3 9 Reread Delay Delay 500 MS Default Delay 750 MS Delay 1000 MS ...

Page 20: ...Element P303BT User Guide I Page 20 of 53 4 Data Formatting 4 1 General Configuration Add CR Add LF Add CRLF Add TAB ...

Page 21: ... hexadecimal values of a desired prefix and then scan the Save barcode Refer to Appendix 2 ASCII Table for hexadecimal values of characters Example Set the custom Prefix to ODE 1 Check the hex values of ODE in the ASCII Table ODE 4F 44 45 2 Scan the Set Custom Prefix barcode 3 Scan the numeric barcodes 9 9 4 F 4 4 4 and 5 in Appendix 3 4 Scan the Save barcode 5 Note 99 indicates all symbollogies ...

Page 22: ...uffix and then scan the Save barcode Refer to Appendix 2 ASCII Table for hexadecimal values of characters Example Set the custom Suffix to ODE 1 Check the hex values of ODE in the ASCII T able ODE 4F 44 45 2 Scan the Set Custom Suffix barcode 3 Scan the numeric barcodes 9 9 4 F 4 4 4 and 5 in Appendix 3 4 Scan the Save barcode 5 Note 99 indicates all symbologies 4 4 Clear All Prefix and Suffix Cle...

Page 23: ... Default Disable Code 128 Message Length Message length can be set to the maximum value or minimum value The value between the maximum and the minimum is valid The maximum value and minimum value can be set using Programming Command Please check the programming command guide for the detail Code 128 max length command 020A03 The parameter of this command can be set from min to 90 Code 128 min lengt...

Page 24: ...length with the last one as its check digit used to verify the accuracy of the data Transmit EAN 8 Check Digit Default Do Not Transmit EAN 8 Check Digit Add On Code An EAN 8 barcode can be augmented with a two digit or five digit add on code to form a new one In the examples below the part surrounded by blue dotted line is an EAN 8 barcode while the part circled by red dotted line is add on code ...

Page 25: ...I Page 25 of 53 Enable 2 Digit Add On Code Disable 2 Digit Add On Code Default Enable 5 Digit Add On Code Disable 5 Digit Add On Code Default Add On Code Required EAN 8 Add On Code Required EAN 8 Add On Code Not Required Default ...

Page 26: ...here is a space between barcode and addenda When this feature is disabled there is no space Enable ENA JAN 8 Addenda Separator Default Disable ENA JAN 8 Addenda Separator UPC 5 4 EAN 13 Enable Disable EAN 13 Enable EAN 13 Default Disable EAN 13 Transmit Check Digit Transmit EAN 13 Check Digit Default ...

Page 27: ...ansmit EAN 13 Check Digit Add On Code Enable 2 Digit Add On Code Disable 2 Digit Add On Code Default Enable 5 Digit Add On Code Disable 5 Digit Add On Code Default Add On Code Required EAN 13 Add On Code Required EAN 13 Add On Code Not Required Default ...

Page 28: ...n this feature is disabled there is no space Enable ENA JAN 13 Addenda Separator Default Disable ENA JAN 13 Addenda Separator ISBN Translate When enable this feature and is scanned EAN 13 Book land symbols are translated into their equivalent ISBN number format Enable ISBN Translate Disable ISBN Translate Default 5 5 UPC E Enable Disable UPC E0 E1 ...

Page 29: ... I Page 29 of 53 Enable UPC E0 Default Disable UPC E0 Enable UPC E1 Disable UPC E1 Default Enable ENA JAN 8 Addenda Separator Default Disable ENA JAN 8 Addenda Separator UPC UPC E0 Check Digit Enable UPC E0 Check Digit Default ...

Page 30: ...nd expands the UPC E code to the 12 digits UPC A format Enable UPC E0 Expand Disable UPC E0 Expand Default UPC E0 Addenda Required When required is scanned the scanner will only read UPC E barcodes that have addenda Enable UPC E0 Required Disable UPC E0 Required Default UPC E0 Addenda Separator ...

Page 31: ...m The number system digit of UPC symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will be not transmitted Enable UPC E0 Number System Default Disable UPC E0 Number System UPC E0 Addenda Enable 2 Digit Addenda Disable 2 Digit Addenda Default Enable 5 Digit Addenda ...

Page 32: ...enda Default 5 6 UPC A Enable Disable UPC A Enable UPC A Default Disable UPC A UPC A Check Digit Enable UPC A Check Digit Default Disable UPC A Check Digit UPC A Addenda Required When required is scanned the scanner will only read UPC E barcodes that have addenda ...

Page 33: ...t UPC A Addenda Separator Enable UPC A Separator Default Disable UPC A Separator UPC A Number System The number system digit of UPC symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will be not transmitted Enable UPC A Number System Default ...

Page 34: ...Guide I Page 34 of 53 Disable UPC A Number System UPC A Addenda Enable 2 Digit Addenda Disable 2 Digit Addenda Default Enable 5 Digit Addenda Disable 5 Digit Default 5 7 Interleaved 2 Of 5 Enable Disable Interleaved 2 Of 5 ...

Page 35: ...and Please check the programming command guide for the detail Max length command 020404 The parameter of this command can be set from min to 80 Min length command 020403 The parameter of this command can be set from 2 to max Example Set the Barcode Message length of the minimum value is 10 the maximum value is 25 Programming command Max 02040425 Min 02040310 Interleaved 2 Of 5 Check Digit No Check...

Page 36: ... set from 1 to max Example Set the Barcode Message length of the minimum value is 10 the maximum value is 25 Programming command Max 02080325 Min 02080210 5 9 Industrial 2 Of 5 Enable Disable Industrial 2 Of 5 Enable Industrial 2 Of 5 Disable Industrial 2 Of 5 Default Message Length Message length can be set to the maximum value minimum value The value is valid between the maximum and the minimum ...

Page 37: ... is 10 the maximum value is 25 Programming command Max 02060325 Min 02060210 5 10 Code 39 Enable Disable Code 39 Enable Code 39 Default Disable Code 39 Transmit Start Stop Character Transmit Start Stop Character Do Not Transmit Start Stop Character Default Code 39 Check Character No Check Char Default ...

Page 38: ...re transmitting to host When the scanner encounters a Code 39 barcode with append character ex Space character it buffers the data until it reads a Code 39 barcode which does not have append character Then the data is transmitted in the order that the barcodes were read Enable Append Disable Append Default Code 39 Full ASCII Enable Code 39 Full ASCII Disable Code 39 Full ASCII Default ...

Page 39: ... maximum value is 25 Programming command Max 02030825 Min 02030710 5 11 Coda Bar Enable Disable Coda Bar Enable Coda Bar Default Disable Coda Bar Message Length Message length can be set to the maximum value minimum value The data between the maximum and the minimum is valid The maximum value and minimum value can be set using Programming command Please check the programming command guide for the ...

Page 40: ... 40 of 53 Transmit Start Stop Character Do Not Transmit Start Stop Character Default Coda bar Check Character No Check Char Default Validate And Transmit Validate No Transmit 5 12 Code 93 Enable Disable Code 93 Enable Code 93 Default ...

Page 41: ...of this command can be set from 0 to max Example Set the Barcode Message length of the minimum value is 10 the maximum value is 25 Programming command Max 020D0325 Min 020D0210 Code 93 Append This function allows the scanner to append several Code 93 barcode data together before transmitting to host When the scanner encounters a Code 93 barcode with append character ex Space character it buffers t...

Page 42: ...k the programming command guide for the detail GS1 128 max length command 020B03 The parameter of this command can be set from min to 80 GS1 128 min length command 020B02 The parameter of this command can be set from 0 to max Example Set the Barcode Message length of the minimum value is 10 the maximum value is 25 Programming command Max 020B0325 Min 020B0210 5 14 Code 11 Enable Disable Code 11 En...

Page 43: ...03BT User Guide I Page 43 of 53 Two Check Digits Default 5 15 PDF 417 Enable Disable PDF 417 Enable PDF 417 Default Disable PDF 417 Enable Disable Micro PDF 417 Enable Micro PDF 417 Disable Micro PDF 417 Default ...

Page 44: ...age length can be set to the maximum value minimum value The data is valid between the maximum and the minimum is valid The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail QR max length command 023703 The parameter of this command can be set from min to 7089 QR min length command 023702 The parameter of this command can...

Page 45: ...he minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Data Matrix max length command 023603 The parameter of this command can be set from min to 3116 Data Matrix min length command 023602 The parameter of this command can be set from 1 to max Example Set the Barcode Message length of the minimum value is 10 the...

Page 46: ...amming command Please check the programming command guide for the detail Maxi Code max length command 023403 The parameter of this command can be set from min to 150 Maxi Code min length command 023402 The parameter of this command can be set from 1 to max Example Set the Barcode Message length of the minimum value is 10 the maximum value is 25 Programming command Max 02340325 Min 02340210 5 19 Az...

Page 47: ... set using Programming command Please check the programming command guide for the detail Aztec max length command 023306 The parameter of this command can be set from min to 3832 Aztec min length command 023305 The parameter of this command can be set from 1 to max Example Set the Barcode Message length of the minimum value is 10 the maximum value is 25 Programming command Max 02330625 Min 0233051...

Page 48: ...OD10 transmit check digit 66 Code 39 A0 Transmit barcodes as is Full ASCII disabled no parity check 62 A1 One check digit MOD43 transmit check digit 62 A3 One check digit MOD43 do not transmit check digit 62 A4 Full ASCII enabled no parity check 62 A5 Full ASCII enabled transmit check digit 62 A7 Full ASCII enabled do not transmit check digit 62 Codebar F0 Standard Codebar 61 F2 Transmit check dig...

Page 49: ...art character 73 Reference ISO IEC 15424 2008 Information technology Automatic identification and data capture techniques Data Carrier Identifiers including Symbology Identifiers 6 2 Appendix 2 ASCII Table Hex Dec Char Predefined keystrokes CTRL X functions 00 0 NUL Null char Reserved CTRL 01 1 SOH Start of Header Enter CTRL A 02 2 STX Start of Text Caps Lock CTRL B 03 3 ETX End of Text ALT Make C...

Page 50: ...RL 1E 30 RS Request to Send F9 CTRL 1F 31 US Unit Separator F10 CTRL Hex Dec Char 20 32 SP Space 21 33 Exclamation Mark 22 34 Double Quote 23 35 Number Sign 24 36 Dollar Sign 25 37 Percent 26 38 Ampersand 27 39 Single Quote 28 40 Right Closing Parenthesis 29 41 Right Closing Parenthesis 2a 42 Asterisk 2b 43 Plus 2c 44 Comma 2d 45 Minus Dash 2e 46 Dot 2f 47 Forward Slash 30 48 0 31 49 1 32 50 2 33 ...

Page 51: ...81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X 59 89 Y 5a 90 Z 5b 91 Left Opening Bracket 5c 92 Back Slash 5d 93 Right Closing Bracket 5e 94 Caret Circumflex 5f 95 _ Underscore 60 96 Grave Accent 61 97 a 62 98 b 63 99 c 64 100 d 65 101 e 66 102 f 67 103 g Hex Dec Char 68 104 h 69 105 i 6a 106 j 6b 107 k 6c 108 l 6d 109 m 6e 110 n 6f 111 o 70 112 p 71 113 q ...

Page 52: ...BT User Guide I Page 52 of 53 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7a 122 z 7b 123 Left Opening Brace 7c 124 Vertical Bar 7d 125 Right Closing Brace 7e 126 Tilde 7f 127 DEL Delete ...

Page 53: ...Element P303BT User Guide I Page 53 of 53 6 3 Appendix 3 Digit Barcodes 0 1 2 3 4 5 6 7 8 9 A B C D E F ...

Reviews: