![ElektroPhysik MiniTest 440 Technical Reference And Operating Manual Download Page 24](http://html.mh-extra.com/html/elektrophysik/minitest-440/minitest-440_technical-reference-and-operating-manual_2386835024.webp)
Data storage
ElektroPhysik
E-19
【
6.6
】
Data storage
When the storage file is set, users can save the measuring data to the file,
the detailed procedure is as follows:
1.
Make sure the measurement is correct.
2.
Press “
OK
”, the measured data will be saved automatically.
Note: The process is available when the measurement icon
disappeared
7 Measuring technology
【
7.1
】
Measuring methods
The instrument provides many measuring methods.
1.
Single point measuring method: use the probe to measure any point
of the work-piece to be measured and the displayed value is the thickness.
2.
Two point measuring method: Perform two measurements on the
same point of the measured surface, in the second measurement, splitting
plane of the probe should be 90 degree, take the minimum as the thickness
value
3.
Multiple point measurement method: perform several measurements
in a circle about 30mm in diameter and take the minimum value as the
thickness value.
4.
Continuous measurement methods: apply the single point
measurement method, and take measurements continuously along the
designated route, the intervals should be less than 5mm, and take the
minimum value as the work-piece's thickness.
Summary of Contents for MiniTest 440