EL 9000 B 15U/24U Series
Setting
P. Description
PSI / EL system
9
This item will only be displayed if the device is set as
MASTER
Must remain deactivated for correct operation of the cabinet.
Repeat master init.
10
This item will only be displayed if the device is set as
MASTER
Touch area “
Initialize
” will repeat the initialisation of the master-slave system
in case the automatic enumeration of the slave units by the master is once
unsuccessful so the system would have less total power than expected or has
to be repeated manually in case the master unit couldn’t detect a missing slave
3.4.3.2
Menu “User Events”
See
„3.6.2.1 User defined events“ on page 59
3.4.3.3
Menu “Profiles”
See
„3.9 Loading and saving a user profile“ on page 61
.
3.4.3.4
Menu “Overview”
This menu page displays an overview of the set values (U, I, P or U, I, P, R) and alarm settings as well as settings
limits. These can only be displayed, not changed.
3.4.3.5
Menu “About HW, SW...”
This menu page displays an overview of device relevant data such as serial number, article number etc., as well as
an alarm history which lists the number of device alarms that probably occurred since the device has been powered.
3.4.3.6
Menu “Function Generator”
See
„3.10 The function generator“ on page 62
.
3.4.3.7
Menu “Communication”
This submenu offers settings for digital communication via the optional or built-in interface. The button for the in
-
stalled interface module opens one or more settings pages, depending on the interface type. There are furthermore
adjustable communication timeout settings, of which the one for USB can make it possible to successfully transfer
fragmented messages using higher values. In the screen for “Com Protocols” it is possible to enable both or dis
-
able one of the two supported communication protocols, ModBus RTU and SCPI. This can help to avoid mixing
both protocols and to receive unreadable messages, for example when expecting a SCPI response and getting
a ModBus RTU response instead.
For all Ethernet interfaces with two ports: „P1“ is related to port 1 and „P2“ to port 2, like printed
on the module face. Two-port interfaces will use one IP only, because they operate as Ethernet
switch
IF Level 1
Description
Profibus DP
Node Address
Selection of the Profibus or node address of the device within range 1...125 via
direct input
Function Tag
String input box for a user-definable text which describes the Profibus slave function
tag. Max. length: 32 characters
Location Tag
String input box for a user-definable text which describes the Profibus slave location
tag. Max. length: 22 characters
Installation Date
String input box for a user-definable text which describes the Profibus slave instal
-
lation date tag. Max. length: 40 characters
Description
String input box for a user-definable text which describes the Profibus slave.
Max. length: 54 characters
IF Level 1
Level 2
Description
CANopen
Node Address
Selection of the CANopen node address in the range 1...127
Baud Rate
AUTO
Automatic detection of the bus baud rate or speed
LSS
Automatically sets baud rate and node address
Manual
Manual selection of the baud rate that is used by the CANopen interface.
Possible selections: 10 kbps, 20 kbps, 50 kbps, 100 kbps, 125 kbps, 250
kbps, 500 kbps, 800 kbps, 1Mbps (1Mbps = 1 Mbit/s, 10 kbps = 10 kbit/s)