background image

Page 23 of 24                                                                                                            M8165 Issue 1.1 

 

11. Customer Support. 
 

For help and support in using your EME Mantle, please contact 
Electrothermal at the following address. 
 
 

Electrothermal. 

Electrothermal House. 
Unit12A, Purdeys Way. 
Purdeys Industrial Estate. 
Rochford, 
Essex.  SS4 1ND 
Great Britain. 
 
Tel +44(0)1702 303350 
Fax+44(0)1702 468731 
 

 

Email: General enquiries: 

[email protected]

 

 

 

Orders

[email protected]

 

 

 

Help with existing products: 

[email protected]

 and 

[email protected]

 

 

 

www.electrothermal.com 

 

For the America’s and Canada, contact: 
Techne Incorporated,

 3 Terri Lane, 

Suite 10 Burlington, NJ 08016 USA. 

 

Toll free:800-225-9243Tel: 609-589-2560 
Fax: 609-589-2571 
Email

[email protected]

 

Http 

www.techneusa.com 

 

  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for EME Series

Page 1: ...Page 1 of 24 M8165 Issue 1 1 EME SERIES ELECTROMANTLES INSTRUCTION BOOK ...

Page 2: ...on of Conformity Page 24 Appendix A Decontamination Certificate Page 22 The copyright of this Instruction book is the property of Electrothermal This Instruction book is supplied by Electrothermal on the express understanding that it is to be used solely for the purpose for which it is supplied It may not be copied used or disclosed to others in whole or part for any purpose except as authorised i...

Page 3: ...ded with ventilation slots underneath and around the rim to ensure a low enclosure surface temperature The heating element is retained in thermal Rockwool to create a heating cartridge that facilitates very easy replacement in the event of any damage All EME s are supplied with support rods and clamps 1 5 Electrothermal offers a comprehensive mantle range with the Standard cool to touch vented cas...

Page 4: ...pment are suitably trained before use 2 2 Symbols defined Caution risk of danger See note or adjacent symbol This symbol adjacent to an indication lamp means mains power Off On when lamp non illuminated illuminated Protective conductor terminal to be earthed Do not loosen or disconnect This symbol adjacent to a switch denotes the Off condition for mains power Caution risk of electric shock This sy...

Page 5: ...ion to your company s safety and legislative health safety procedures and all associated legislation applicable to your areas of operation Check laboratory procedures for substances being heated and ensure all hazards e g explosion implosion or the release of toxic or flammable gases that might arise have been suitably addressed before proceeding When heating certain substances the liberation of h...

Page 6: ...lds Keep all metal objects and magnetic data devices e g credit cards away from the stirrer unit The equipment is not spark flame or explosion proof and has not been designed for use in hazardous areas in terms of BSEN 60079 14 1997 Keep flammable low flash point substances away from the apparatus Do not operate or handle any part of the product with wet hands Keep the Mains cord and moulded IEC p...

Page 7: ...is detailed below First and second Characters EME Series Next Character A unit with stir facility Next Character if Multi bank 3 or 6 3 way or 6 way Next four Characters Flask size in ml 0050 0100 0500 1000 Next Character after the C Controlled Next Character E Earthed screen Last Characters No Characters 230V X1 115V The following family tree outlines product variants ...

Page 8: ... your products Serial and Model Numbers Serial Number Unit Model Cat Number Item No Description Qty 1 EME product 6 way shown 1 2 Mains cord and moulded IEC plug and lead set May differ from illustration depending on variant 1 3 Support rods set 2 of one length and one of another 1 4 Stir bars bag of 3 or 6 EMEA Only 1 5 Instructions book 1 6 Support rod clamps packet 1 ...

Page 9: ...ted See Technical Information Section 8 of this Instructions book 5 1 4 Check the voltage on the product data label on this product unit and those of any accompanying electrical accessory Ensure the rating conforms to your local supply 5 1 5 This product should be connected to a mains supply source which incorporates a RCD or GFCI device that has a tripping current of 30mA or less The RCD or GFCI ...

Page 10: ...enna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 6 ENVIRONMENTAL PROTECTION 6 1 Electrothermal has given due consideration to environmental issues within the design and manufacturing process without compromising en...

Page 11: ...ect the mains cord and moulded IEC plug and lead set to the mains IEC socket 7 1 4 Place a charged clean dry glass vessel of the size indicated on the mantle data plate label in the positions intended for use Wherever possible the glass vessel should be supported within the mantle by means of the support rod and clamp 7 1 5 Switch on the mains electrical supply Adjust the controller regulator knob...

Page 12: ...ing on neon will illuminated in each position when the heaters are in operation Item Description 1 Support Rods and clamps NB for 3 way units the support rod arrangement is as per EME3 way 2 Heating Element 3 Stir speed regulation 4 Mains power on indicator 5 Heating element on 6 Energy regulator control knob 7 Warning Labels Hot surface and refer to Instructions book 8 Fuse holders Contains prote...

Page 13: ...to the required setting NOTE The mains power on indication neon will illuminate The amber heating on neon will illuminate and pulsate dependent on setting in each position when the heaters are in operation 7 2 8 A single stirring module controls the stirring on the EMEA3 Two separate stirrer modules and two controllers are used on the EMEA6 Each controller controlling the stir function on the thre...

Page 14: ...ead set supply cord H05 V V F Replace only with equivalent cable Mains cord and moulded IEC plug and lead set cable Europe AZ6747 3 core earthed ground 2 meters long Moulded IEC plug and Lead set supply cord H05 V V F Replace only with equivalent cable Mains cord and moulded IEC plug and lead set cable USA AZ6746 3 core earthed ground 2 meters long Moulded IEC plug and Lead set supply cord SJT VW ...

Page 15: ...E3 1000ml 3x300 3x300 F5 F10 EMEA3 1000ml 3x300 40 Stir 3x300 40 Stir F6 5 F10 EME6 100ml 6x70 6x60 F3 F5 EMEA6 100ml 6x70 80 Stir 6x60 80 Stir F3 F6 3 EME6 250ml 6x150 6x150 F5 F10 EMEA6 250ml 6x150 80 Stir 6x150 80 Stir F6 3 F10 EME6 500ml 6x200 6x200 F6 5 F15 EMEA6 500ml 6x200 80 Stir 6x200 80 Stir F6 3 F15 EME6 1000ml 6x300 6x300 F10 F10 EMEA6 1000ml 6x300 80 Stir F10 8 1 2 The Ingress protect...

Page 16: ...Page 16 of 24 M8165 Issue 1 1 EMEx3 EMEAx3 1000ml WEIGHT 7 4Kg EMEx6 EMEAx6 0100ml WEIGHT 10 1Kg EMEx6 EMEAx6 250ml WEIGHT 10 1Kg EMEx6 EMEAx6 500ml WEIGHT 12 5Kg EMEx6 EMEAx6 1000ml WEIGHT 12 5Kg ...

Page 17: ...ic electrical safety testing an annual test is recommended as the minimum requirement Regular inspection for damage with particular attention to the mains lead and plug set Routine cleaning of the equipment should be undertaken using a clean cloth DO NOT USE SOLVENTS FOR CLEANING ANY PART OF THIS EQUIPMENT 9 2 Fuse Replacement The mains fuse holder is located at rear your product Refer to Technica...

Page 18: ... mantles contain Rockwool mineral insulation When handling a suitable face mask which bears the CE mark should be used A face mask to BS EN 149 is adequate When handling wear gloves Should skin irritation be experienced it can be lessened by rinsing hands under cold running water before washing For further information refer to guidance note EH46 published by HMSO and technical data sheets availabl...

Page 19: ...ort Refer to section 11 If the equipment has been exposed to contamination the Responsible Body is responsible for carrying out appropriate decontamination If hazardous material has been spilt on or inside the equipment decontamination should only be undertaken under the control of the Responsible Body with due recognition of possible hazards Before using any cleaning or decontamination method the...

Page 20: ...and moulded IEC plug and lead set USA 115V AC EMEA6 0500 CEBx1 EME6 1000 CEBx1 EMEA6 0500 CEx1 EMEA6 1000 CEx1 1 AZ6746 Mains cord and moulded IEC plug and lead set USA 115V AC 1 AZ6747 Mains cord and moulded IEC plug and lead set Europe 230V AC 1 AZ9021 Solid state Simmerstat assembly 90 250V AC 1 AZ9033 Fuse F15A 10 AZ9034 Fuse F10A 10 AZ9035 Fuse F8A 10 AZ9036 Fuse F6 3A 10 AZ9038 Fuse F0 5A 10...

Page 21: ...Page 21 of 24 M8165 Issue 1 1 Accessories AZ9124 RCD Safety Adapter rated at 230Volts 50Hz 13Amp Max Load 3Kw 1 AZ9149 GFCI Ground Fault Circuit Interrupter 125Volts 60Hz 15Amps 1 ...

Page 22: ...estions by deleting YES NO as applicable and by providing details in section 2 below A Blood body fluids Pathological specimens YES NO Provide details if YES B Biodegradable material that could become a hazard YES NO Provide details if YES C Other biohazard YES NO Provide details if YES D Chemical or substances hazardous to health YES NO Provide details if YES E Radioactive substances State name s...

Page 23: ...Britain Tel 44 0 1702 303350 Fax 44 0 1702 468731 Email General enquiries info electrothermal com Orders orders electrothermal com Help with existing products help electrothermal com and electrothermalhelp bibby scientific com www electrothermal com For the America s and Canada contact Techne Incorporated 3 Terri Lane Suite 10 Burlington NJ 08016 USA Toll free 800 225 9243Tel 609 589 2560 Fax 609 ...

Page 24: ...it12A Purdeys Way Purdeys Industrial Estate Rochford Essex SS4 1ND Great Britain Tel 44 0 1702 303350 Fax 44 0 1702 468731 Email General enquiries info electrothermal com Orders orders electrothermal com Help with existing products help electrothermal com and electrothermalhelp bibby scientific com www electrothermal com For the America s and Canada contact Techne Incorporated 3 Terri Lane Suite 1...

Reviews: