LCD Hour Meter

Dimensions

2.00 [50.8]

1.86 [47.3]

.16 [4.0]

.02 [0.5]

1.76 [44.7]

1.50 [38.0]

.31 [8.0]

1.10 [27.9]

.87 [22.1]

.48 [12.1]

1.31 [33.4]

.97 [24.7]

Available Icons

Panel Cutout: 1.79” [45.5mm] x 0.89” [22.6mm]

Recommended Panel Thickness: 0.875” [22.2mm]

SERVICE

CHANGE

OIL

OIL FILTER

AIR FILTER

LAMP

MUFFLER

Specifications

Display:

  Figures: 8 LCD digits 0.32” [8mm] high

 

Annunciators Icon: A choice of 7 Icons 0.08” [2mm] high

Reset:

 

Remote, manual & non-reset. Manual reset enable is available  

 

on some models

Speed:

  Low speed: 0-40 counts per second (min. 12.5ms-on, 12.5ms-off

 

High speed: 0-500 counts per second (min. 1.0 ms-on, 1.0 ms-off

Inputs:

  Switch (no voltage)

 

DC Voltage:

 

 

Absolute voltage range:  

-0.5 VDC, minimum to  

 

 

 

 

 

30.0VDC, maximum

 

 

VIH: 

 

 

3.0 VDC, maximum

 

 

VIL: 

 

 

1.0 VDC, minimum

 

High Voltage AC/DC: 

 

 

Absolute Maximum voltage:   300VAC/VDC

 

 

VIH: 

 

 

10VDC/20 VAC, max.

 

 

VIL: 

 

 

3VDC/3 VAC, minimum

Power:

  Internally powered models: Self powered

         

(+15yrs lithium battery)

 

Externally Powered models: 5-28 VDC , externally supplied

 

Absolute Maximum external power: 30.0 VDC

Output:

  Format: Open-Drain MOSFET with Source connected to 

 

Common (see note 3)

 

Maximum Withstanding voltage: 30VDC, reference to Common

 

Maximum Load current: 0.1Amp

EEPROM: 

(When installed) 40 years

 

 

Maximum data writes: 100,000

Battery Life:

  

15 years +

Mounting:  

Panel with clip

Terminations:

  

Terminal block

Weight:

    

2 oz. [57g]

Environmental:

       Temp. (Storage & Operating):

 

 

-4˚F to + 140˚F [-20˚C to +60˚C]

 

                 Humidity:  

0 to 95% RH, non-condensing

Vibration:

Operating: 

 

10 to 55 Hz, 0.01” [0.25mm]

 

 

 

 

double amplitude

 

 

 Non-operating:        10 to 55 Hz, 0.03” [0.75mm]    

 

 

 

 

double amplitude

Shock:

   

 Operating: 

10G’s

 

 

Non-operating: 

30G’s

Dielectric: 

1000 VAC 50/60Hz for 1 minute

Accuracy: 

100% (provided signal meets stated parameters)

EMC Compliance:

  EN61326:1997 with A1: 1998 & A2:2001 for industrial  

 

 

environments

Enclosure: 

 

NEMA 4/4X, 12, & IP66 compliance (from the front)  

 

 

when properly mounted using the optional gasket 

Approvals:

 

CE compliant, UL & cUL recognized

Environmental Compliance:

 Compliant to the European WEEE & RoHS 

Notes

When interfacing the Model 63 with a Solid State Relay or AC Sensor, the leakage current needs to be considered.  Contact the factory or see the 
application note at www.redingtoncounters.com for further information.
The Absolute Voltage Range and the Absolute Maximum Voltage are the voltages at which operation beyond the specified limits may result in  
damage to the unit.

3. 

Operates like open-collector NPN.  Care should be taken when interfacing to this input since there is no current limiting protection.

1.

2.

Reviews: