33
6204
15
6204
16
6204
17
SHOW MCU COM.
Select the SHOW MCU COM. row and press the
knob.
The display shows the status of the communica-
tion to and from the frequency control such as
actual speed and set speed values.
For detailed information, see next page.
RESET MCU
Reset frequency control from the error code by
selecting the RESET MCU row and pressing the
knob. The reset will take a few seconds.
The square which lights up to the right of the
menu bar indicates that there is a error code in
the DLCU.
SHOW SINGLE
Select the SHOW SINGLE row and press the
knob. The display shows the status of the com-
munication to and from the slot meter.
For detailed information, please contact your
supplier.
SHOW COM. PORTS
Select the SHOW COM. PORTS row and press
the knob. Possible communication ports are
shown in the display. Select a port, then press
the knob to test that port. Note that the ports
“send” and “receive” must be strapped for the
test to work.
*SERVICE*
01.06.00.00
RESET DLCU
SHOW MCU COM.
RESET MCU
SHOW SINGLE
SHOW COM.PORTS
WEIGHT CALIBRATION
MOTOR STATUS
FROM MOTOR 10000100
FROM MOTOR 000000CD
ACTUAL SPEED RPM
0
SET SPEED RPM
0
BACK=PRESS KNOB
*SERVICE*
01.07.00.00
SHOW MCU COM.
RESET MCU
SHOW SINGLE
SHOW COM.PORTS
WEIGHT CALIBRATION
MEASURE WEIGHT
15
16
17
Program unit