Function check

39

10 Function check

May only be carried out by qualified personnel.

A function check must be made when the installation is finished and before the machine can be
used.

Check the automatic stop of the machine

• Start the machine.

• Check if the micro switches are working properly:

The machine must stop if the door is opened.

Check the direction of rotation (only on machines with 3–phase power supply)

• Demount the lower back panel of the machine.

• Check that the direction of the fan wheel is correct.

fig.7118

29

Summary of Contents for T5290

Page 1: ...Installation manual Tumble dryer T5290 Type N2 438 9054 00 EN Installation manual in original language 2011 09 12 ...

Page 2: ......

Page 3: ...ection 23 8 1 Fasten the label 23 8 2 General 23 8 3 Gas installation 24 8 4 Table of pressure and adjustment 25 8 5 Test run 26 8 6 Converting instructions 27 8 7 Data label 29 9 Electrical connection 30 9 1 Electrical installation 30 9 2 Single phase connection 31 9 3 Three phase connection 32 9 4 Electrical connections 33 9 5 Functions for I O cards 34 9 5 1 Central payment 22J 34 9 5 2 Central...

Page 4: ......

Page 5: ...items are left at a temperature that ensures that the items will not be damaged Remove all objects from pockets such as lighters and matches WARNING Never stop the machine before the end of the drying cycle unless all items are quickly removed and spread out so that the heat is dissipated Adequate ventilation has to be provided to avoid the back flow of gases into the room for appliances burning o...

Page 6: ...cautions In order to prevent damage to the electronics and other parts that may occur as the result of condensation the machine should be placed in room temperature for 24 hours before being used for the first time ...

Page 7: ...M C D E J G I F 1 2 7 6 3 5 7 6 3 4 5 1 Operating panel 2 Door opening 580 mm 3 Electrical connection 4 Gas connection 5 Exhaust connection 6 Steam in 7 Steam out A B a B b C D E F G mm 710 1155 1335 1675 725 780 140 1310 H I J K L M N mm 70 155 1380 55 355 685 605 ...

Page 8: ...am kW 25 Air consumption Electric heating 13 5 kW m3 h 380 Air consumption Electric heating 18 0 kW m3 h 450 Air consumption Gas heating m3 h 550 Air consumption Steam heating m3 h 640 Airborne sound level dB A 70 Pressure drop Electric heating 13 5 kW Max Pa 400 Pressure drop Electric heating 18 0 kW Max Pa 350 Pressure drop Gas heating Max Pa 350 Pressure drop Steam heating Max Pa 350 2 3 Connec...

Page 9: ...tween the machine and pallet There are two bolts in the front of the machine and two in the back of the machine Remove the lower front panel and remove the two bolts in the front of the machine Remove the lower back panel and remove the two bolts in the back of the machine Remount the panels when done fig 7189A Remove the machine from the pallet Note When removing the machine handle it with care T...

Page 10: ...ersonnel The figure shows minimum distance to a wall and or other machines Min 150 mm 5 7 8 inch Min 20 mm 13 16 inch Max 50 mm 1 15 16 inch 500 mm 20 inch 10 mm 3 8 inch 10 mm 3 8 inch fig 7187 3 3 Mechanical installation Level the machine with the feet of the machine The maximum height adjustment of the feet is 15 mm fig 7188 ...

Page 11: ...e machine model to the foundation using four x M10 set screws If the four fittings is not supplied order kit Nr 487193544 Fasten the machine to the fittings Note Marine installation is not applicable for gas heated machines 15 3 mm 9 16 inch 43 3 mm 1 11 16 inch 1065 mm 41 15 16 inch 1005 6 mm 39 5 8 inch 73 mm 2 7 8 inch 677 1 mm 26 5 8 inch 617 6 mm 24 5 16 inch 45 mm 1 3 4 inch M10 ...

Page 12: ...Disconnect the power to the machine Demount the hinges and remove the door Remove the upper hinge first fig 7166 Remove the screws on the front panel and carefully loosen the panel Disconnect the door switch cable and remove the panel fig 7179A ...

Page 13: ... 13 Move the door switch cable to the opposite site Note The plastic plug MUST be placed in the hole where the door switch cable was before fig 7170 Loosen the nuts and move the two brackets to the opposite side fig 7171 ...

Page 14: ... 3 4 fig 7172 Move the four metal clips from the right side to the left side fig 7174 Connect the door switch cable and remount the front panel Fasten the hinges and mount the door on the opposite side than before Connect the power to the machine Test run the machine ...

Page 15: ...The heated air passes through the garments and the drum holes The air then flows outh through a lint filter positioned below the drum Then the air is evacuated through the fan and exhaust system Dimension for air evacuation A is 200 mm A fig W00264 Note It is very important that the machine gets enough fresh air in order to get the best drying result ...

Page 16: ...m To avoid draught in the room it is important to place the air inlet behind the machine The area of the air inlet opening must be five times the size of the exhaust pipe area The area of the inlet opening is the area through which the air can flow without resistance from the grating slatted cover 5 x A A fig 7183 Note Gratings slatted covers often block half of the total fresh air vent area Remem...

Page 17: ...ot be vented into a wall a ceiling or a concealed space of building The exhaust duct must lead clear of the building as condensation may cause frost damage to the building The exhaust duct must lead to the outdoors The exhaust duct must be placed in such a way that it is protected on the outside The exhaust duct must be smooth on the inside low air resistance The exhaust duct must have gentle bend...

Page 18: ... several machines shall use the same exhaust duct the exhaust duct must increase after each machine Number of machines 1 2 3 4 5 6 7 8 9 10 Exhaust duct mm 200 280 315 355 400 450 475 500 535 560 Minimum area of fresh air intake m2 0 15 0 30 0 45 0 60 0 75 0 90 1 05 1 20 1 35 1 50 The exhaust duct diameter must not be reduced ...

Page 19: ...th 25 m outlet pipe and two 90 degree bends Each bend is equal to 2 5 m If more than two bends is needed the length should maximum be shortened with 2 5 m per bend If the outlet pipe is longer or the ventilation is not properly designed we recommend to clean the outlet pipes periodically The exhaust pipes shall be short in order for the machine to work in the best way All cover plates must be moun...

Page 20: ...valve a and a dirt collector c in the brach pipe 5 6 a b N M b a c L fig 7194 Condensate return It is important that the brach pipe for condensed water on return to the main condensate pipe has a descending gradient and is lower than the outlet connecting branch 6 Mount a dirt collector b in the return pipe Mount a mechanical water discharger behind the dirt collector c Mount a plug valve a Mount ...

Page 21: ...il on the machine Hold the calorifier towards the machine and remount the supporting rail Make sure that it grasps the calorifier Fasten the calorifier into the supporting rail with the screws Note There must be no space between the machine and the calorifier Mount the back plate Attatch the pressure hoses to the machines inlet and outlet connecting branches It is important to support the inlet an...

Page 22: ...22 Steam connection When ready Leak test the system Clean the dirt collectors Perform a function chek ...

Page 23: ...regul ations Art No GB IE Read the technical instructions before installing the appli ance Read the user instructions before lighting the appliance This appliance may only be installed in a room if the room meets the appropriate ventilation require ments specified in the national installation regulations Art No fig 7113 8 2 General May only be carried out by qualified personnel Mount a shut off va...

Page 24: ...MK Republic of Macedonia DE Germany MT Malta DK Denmark NL Netherlands EE Estonia NEC Non european countries ES Spain NO Norway FI Finland PL Poland FR France PT Portugal GB United Kingdom RO Romania GR Greece SE Sweden HR Croatia SI Slovenia HU Hungary SK Slovakia IE Ireland TR Turkey You should check the kind of energy gas that is available in your place There are many gas types of the same kind...

Page 25: ...2 4 490375645 FI NL RO BE CH CZ IE IT ES FR GR GB HR LT NL PT SI SK AT DE LU Propan and butane mixture I3 28 30 for butane and 37 for Propane No regulation 2 3 490375643 BE CH CY CZ ES FR GB GR IE IT LT LU LV PT SK SI Natural gas Gas category Inlet pressure mbar Burner pressure mbar Injector size mm Air reducing plate mm Label number May be available in following countries I2H I2E 20 8 4 0 4903756...

Page 26: ...onnect a manometer to the measuring tap Select a program that uses heat Start the machine Check the nozzle pressure see table If necessary adjust the regulator setting screw 4 behind the cover screw 3 Replace the cover screw 3 if removed Check that the gas is burning evenly 2 3 4 fig 7120 ...

Page 27: ... the nozzle 1 Mount the new supplied nozzle 1 fig 7127 21 Loosen the measuring branch screw 2 1 4 turn connect a manometer to the measuring branch Connect the power to the machine and select a program with heat Start the machine Set the correct nozzle pressure according to the table on setting screw 4 under the cover screw 3 2 3 4 fig 7120 22 ...

Page 28: ...28 Gas connection Check that the gas flame burns evenly Mount the cover screw 3 Remount the lower back panel ...

Page 29: ...O I2H GB ES GR IE IT PT AT LV HU IS SK I2H DE PL LU I2E LL PIN No 359BS703 MANIF PRESSURE 9 MBAR INJECT OR Ø2 58 MM NATURAL GAS G20 INLET PRES 20 MBAR CAL V AL 37400 KJ M3 DK NO SE FI GB ES GR I E IT PT AT 12H 20 MBAR DE 12E LL 20MBAR ID nr 359BQ491 MANIF PRESSURE 10 MBAR INJ ECTOR Ø3 10 MM NATURAL GAS G20 20 MBAR INLET PRES 20 MBAR CAL VAL 37400 KJ M3 10A 50Hz 432XXXXXXXX 432XXXXXX 5XXX Product n...

Page 30: ...t your machine across an earth leakage circuit breaker please remember the following contact a skilled authorised installation company to ensure that the appropriate type of breaker is chosen and that the dimensioning is correct for maximum reliability connect only one machine per earth leakage circuit breaker it is important that the earth wire is properly connected including to the earth leakage...

Page 31: ...r plate from the supply unit Connect the earth and other wires as shown 1NAC 1AC 1AC L1 L2 N When the installation is completed remount the cover plate and check that the drum is empty that the machine operates by turning on the mains switch and start a program with heat ...

Page 32: ...rom the supply unit Connect the earth and other wires as shown 3AC 3AC L1 L2 L3 3NAC 3NAC L1 L2 L3 N When the installation is completed remount the cover plate and check that the drum is empty that the machine operates by turning on the mains switch and start a program with heat ...

Page 33: ...18 9 35 440 480V 3 60 13 5 14 5 20 440 480V 3 60 18 0 19 0 35 230 240V 3 50 60 18 0 19 0 50 230 240V 3 50 60 13 5 14 5 50 230 240V 1 50 60 13 5 14 3 63 230 240V 1 50 60 18 0 18 8 100 200V 3N 50 60 13 5 14 4 50 Electric heating 200V 3N 50 60 18 0 18 8 63 400 415V 3N 50 60 1 0 10 440 480V 3 60 1 0 10 230 240V 3 50 60 1 0 10 230 240V 1 50 60 1 0 10 Gas heating Steam heating 200V 3N 50 60 0 9 10 ...

Page 34: ...chine from a central payment system the payment system must transmit a start pulse to the machine The start pulse can be either 230V or 24V In order to receive a feedback signal once the machine has started 230V or 24V must be connected to connection 19 The feedback signal on connection 18 remains active high during the entire program fig 7440 24 ...

Page 35: ...rmission has been granted to start the machine The signal must remain active high until the machine starts The signal can be either 230V or 24V In order to receive a feedback signal once the machine has started 230V or 24V must be connected to connection 19 The feedback signal remains active high during the entire program P rogra m run fig 7439 25 ...

Page 36: ...36 Electrical connection 9 5 3 External coin meter Central payment 22K The signal received from external coin meters must be a pulse fig 7438 26 ...

Page 37: ...ction 5 Price red the price of the program can be reduced This function has a number of uses including providing reductions during a specific period of the day Whilst the signal remains active high the price of the program is reduced by the percentage entered in the price programming menu fig 7441 27 ...

Page 38: ...ed on the connection console This connection can be used as external control of a fan The terminal for external control is equipped with 220 240V max 100 mA and is intended solely for the operation of a contactor Max connection 100 mA Gnd must not be used for earthing of external board X1 X2 Gnd fig 7154 28 ...

Page 39: ... the machine can be used Check the automatic stop of the machine Start the machine Check if the micro switches are working properly The machine must stop if the door is opened Check the direction of rotation only on machines with 3 phase power supply Demount the lower back panel of the machine Check that the direction of the fan wheel is correct fig 7118 29 ...

Page 40: ...t the machine work for five minutes on a program with heat Check that the heating is working by opening the door and feel if there is heat in the drum Ready to use If all tests are OK the machine is now ready to be used If some of the tests failed or deficiencies or errors are detected please contact your local service organisation or dealer ...

Page 41: ... 1531 43 21 Page 1 2 Försäkran om överensstämmelse Vi Electrolux Laundry Systems Sweden AB SE 341 80 Ljungby Sverige försäkrar under eget ansvar att denna produkt med typbeteckning och enl ovan är tillverkad i överensstämmelse med följande direktiv LVD Directive 2006 95 EC EMC Directive 2004 108 EC GAS Directive 2009 142 EC gäller endast N och WN3 CE Marking Directive 93 68 EEC RoHS Directive 2002...

Page 42: ...H WN3 WD4240H WN3 W4400H W4 H W4600H W4 H W4850H W4 H W41100H W4 H W4280X EXSM X W4350X EXSM X W4600X EXSM X C240 H1 C260 H1 C240R H1 C260R H1 C290R H1 T4130 N1130 T4190 N1190 PD9 N1190 T4250 N2 T4350 N2 T5290 N2 T5550 N2 T5675 N2 Translation table for model name to type of approval 471 1531 43 21 Page 2 2 Ljungby 2011 06 21 Franco Panno Vice President Technical Operations Commercial name Type T43...

Page 43: ...tää uudelleen mutta se sisältää myös materiaaleja jotka pitää käsitellä asianmukaisesti Älä sen vuoksi koskaan laita konetta tai sen osia kotitalousjätteen sekaan sillä se saattaa aiheuttaa terveysriskejä tai vahinkoa ympäristölle Skroting av maskin Når maskinen ikke lenger skal brukes må den leveres til en gjenvinningsstasjon for destruksjon Det går an å gjenbruke mange deler av maskinen men den ...

Page 44: ...lastpage Electrolux Laundry Systems Sweden AB 341 80 Ljungby Sweden www electrolux com laundrysystems Share more of our thinking at www electrolux com ...

Reviews: