• When performing service or replacing parts, the power must be

disconnected.

• When the power is disconnected, the operator must see that the ma-

chine is disconnected (that the plug is removed and remains removed)
from any point to which he has access. If this is not possible, due to
the construction or installation of the machine, a disconnection with a
locking system in the isolated position shall be provided.

• In accordance with the wiring rules: mount a multi-pole switch prior to

the machine to facilitate installation and service operations.

• The openings in the base, shall not be obstructed by a carpet.
• Maximum mass of dry cloth: 6 kg.
• A-weighted emission sound pressure level at working stations: 70 dB

(A).

Gas heated tumble dryer:

• Before installation, check that the local distribution conditions, nature

of gas and pressure and the adjustment of the appliance are
compatible.

• The machine is not to be installed in rooms containing cleaning ma-

chines with perchloroethylene, TRICHLOROETHYLENE or CHLOR-
OFLUOROCONTAINING HYDROCARBONS as cleaning agents.

• If you can smell gas:

– Do not switch on any equipment
– Do not use electrical switches
– Do not use telephones in the building
– Evacuate the room, building or area
– Contact the person responsible for the machine

• Additional requirements for the following countries; AT, BE, BG, HR,

CY, CZ, DK, EE, FI, FR, DE, GR, HU, IS, IE, IT, LV, LT, LU, MT, NL,
NO, PL, PT, RO, SK, SI, ES, SE, CH, TR, UK:
– The appliance can be used in public areas.
– This appliance can be used by children aged from 8 years and

above and persons with reduced physical, sensory or mental capa-
bilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe

Summary of Contents for QuickDry QDC

Page 1: ...User manual Tumble dryer QuickDry QDC Type N1130 Original instructions 438 9096 00 EN 2019 01 02 ...

Page 2: ......

Page 3: ... program has ended 12 4 Error codes 13 5 Maintenance 13 5 1 General 13 5 2 Time for maintenance 13 5 3 Every day 14 5 4 Fresh air intake 15 5 5 Machines with residual moisture control RMC 15 5 6 Condensate machine 15 5 7 Maintenance to be carried out by qualified service personnel 15 6 Disposal information 16 6 1 Disposal of appliance at end of life 16 6 2 Disposal of packing 16 The manufacturer r...

Page 4: ......

Page 5: ... that ensures that the items will not be damaged Remove all objects from pockets such as lighters and matches WARNING Never stop the machine before the end of the drying cycle unless all items are quickly removed and spread out so that the heat is dissipated Adequate ventilation has to be provided to avoid the back flow of gases into the room for appliances burning other fuels including open fires...

Page 6: ...on check that the local distribution conditions nature of gas and pressure and the adjustment of the appliance are compatible The machine is not to be installed in rooms containing cleaning ma chines with perchloroethylene TRICHLOROETHYLENE or CHLOR OFLUOROCONTAINING HYDROCARBONS as cleaning agents If you can smell gas Do not switch on any equipment Do not use electrical switches Do not use teleph...

Page 7: ...truction concerning use of the appliance by a person responsible for their safety Children should be supervised to en sure that they do not play with the appliance 1 1 General safety information In order to prevent damage to the electronics and other parts that may occur as the result of condensation the ma chine should be placed in room temperature for 24 hours before being used for the first tim...

Page 8: ...or selected time has ended The following table shows some examples of available programs and a short description of those Automatic programs Description NORMAL EXTRA DRY DRY and IRON DRY Cotton and terry Normal medium temperature The program will stop when preset dryness selected option is achieved Extra dry Dry or Iron dry LOW EXTRA DRY DRY and IRON DRY Synthetic example of synthetic fabrics poly...

Page 9: ...make sure there are no metal objects such as screws pins etc left Metal objects might cause damage to the drum Load the goods into the machine according to recommendations and close the door Make sure the filter is clean and clean if necessary fig 7361 The maximum load is 6 kg ...

Page 10: ... to start the machine Select program Automatic programs Select program by turning the control knob NORMAL EXTRA DRY LOW EXTRA DRY NORMAL DRY LOW DRY NORMAL IRON DRY LOW IRON DRY Start the machine by pressing the control knob ...

Page 11: ... Select program by turning the control knob NORMAL LOW NO HEATING Start the machine by pressing the control knob After start it is possible to change the time for the selected program Turn the control knob to set the desired time ...

Page 12: ...possible to end a program after start Select END PROGRAM and activate When pressing the control knob start button the program will be ended Status Select STATUS MENU and activate The status menu shows the status for inlet air temp outlet air temp RMC and heat for the machine Statistics Select STATISTICS and activate The statistics menu shows total run hours and trip run hours for the machine Chang...

Page 13: ...tor is too hot The machine will restart automatically when the temperature on the motor is OK if the door has not been opened For other error codes or repeated error codes disconnect the power for 30 seconds If the error code keeps coming back contact authorized service personnel 5 Maintenance 5 1 General It is the responsibility of the owner of the machine the laundry manager to make sure that ma...

Page 14: ...ust be placed out of order until repairs are made Note Contact qualified service personnel to disconnect power from the affected machine Clean the door door gasket and other external parts fig 7362 Check that the filter is clean and unbroken Clean or replace if necessary fig 7363 Remove any lint and dust around the machine ...

Page 15: ...ested when the program has ended 5 6 Condensate machine At regular basis clean the condensing unit from dust and lint Remove the condensing unit from the machine and clean it by rinsing it with water Make sure all dust and lint is removed Clean the area where the air condenser is placed in the machine fig 7160A 5 7 Maintenance to be carried out by qualified service personnel Contact qualified serv...

Page 16: ...ed and that the refrigerator and heat pump components are special waste assimilable with urban waste The symbol on the product indicates that this product should not be treated as domestic waste but must be correctly disposed of in order to prevent any negative consequences for the environment and human health For further information on the recy cling of this product contact the local dealer or ag...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...Electrolux Professional AB 341 80 Ljungby Sweden www electrolux com professional Share more of our thinking at www electrolux com ...