9.3 Other technical data
TOTAL POW‐
ER:
Gas original: G30/G31 (3B/P) 30/30
mbar
567 g/h
Gas replace‐
ment:
G20 (2H) 20 mbar
7,65 kW
Electric supply: 220-240 V ~ 50-60 Hz
Appliance cate‐
gory:
II2H3B/P
Gas connec‐
tion:
R 1/2"
Appliance
class:
3
9.4 Gas burners for LPG G30/G31 30/30 mbar
BURNER
NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS
FLOW g/h
Rapid
2,8
0,95
86
204
Semi-rapid
2,0
0,6
71
145
Auxiliary
1,0
0,33
50
73
9.5 Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Rapid
2,95
0,75
119°
Semi-rapid
1,85
0,6
92
Auxiliary
1,0
0,33
70
10. ENVIRONMENTAL CONCERNS