INSTALLATION
MANUAL
7. Installation
Compressed air connection
The manual stopping valve lockable in
closed position (provided by customer)
should be installed on the machine's
compressed air supply.
The supply pipe should accept a pressure of
at least 1 Mpa (10 bar) (145 psi).
• Connection diameter : rapid action hose
coupling DN 6 (0.24") for hose Ø 6/8 mm.
Nota : to avoid too big head losses, the
compressed air supply pipe should be
bigger in diameter than the coupling
diameter (DN 8 for example); in this case,
put a 6/8-8/10 adapter.
• Advised pressure : 550-700 kPa
(5,5-7 bar) (80-102 psi).
• Minimum pressure: 550 kPa (5,5 bar)
(80 psi).
• Maximum pressure : 700 kPa (7 bar)
(102 psi).
• Consumption 280 l/h.
Compressed
air
Air compressor
Some machines are supplied with an
integrated air compressor.
At first start, it is necessary to turn off the
compressor manometer tap, wait until the
compressor reaches the pressure of 7 bars,
then re-open the valve.
• Regularly check the oil level (every 6
months) and complete if necessary.
• Check the cleanliness of the intake filter,
clean if necessary.
• Purge regularly the water separator tap.
Tap
Water separator