background image

GAS COOKTOP INSTALLATION INSTRUCTIONS

(For 30" & 36" Models)

H

A

B

E

30” Min. *

(76.2 cm)

F

D

C

G

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.

IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.

READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

A01705106 (1609) Rev. A 

English - pages 1-9

Español - páginas 10-18

Français - pages 19-27

Wiring Diagram 28

 If the information in this manual is not followed exactly, a fire or explosion may result 

causing property damage, personal injury or death.

FOR YOUR SAFETY:
—  Do not store or use gasoline or other flammable vapors and liquids in
 

the vicinity of this or any other appliance.

—  WHAT TO DO IF YOU SMELL GAS:
•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone in your building.
•  Immediately call your gas supplier from a neighbor's phone.
 

Follow the gas supplier's instructions.

•  If you cannot reach your gas supplier, call the fire department.
—  Installation and service must be performed by a qualified installer,
 

service agency or the gas supplier.

All dimensions are stated in inches and (cm).

Dimension 

H

 includes a 5" (12,7 cm) space underneath the cooktop for connection to gas supply line.

NOTE: Wiring diagrams for this cooktop are enclosed in this booklet

Figure 1

Printed in China

Gas Cooktop 

Cutout Dimensions

Gas Cooktop 

Dimensions

PRODUCT DIMENSIONS

MODEL

A. WIDTH

B. DEPTH

C. HEIGHT

D. BOX WIDTH

E. BOX DEPTH

30" Gas Cooktop

30 (76,2)

21 ¾ (55,2)

4 ¼ (10,8)

27 (68,6)

19 (48,3)

36" Gas Cooktop

36 (91,4)

21 ¾ (55,2)

4 ¼ (10,8)

33 ¼ (84,5)

19 (48,3)

 CUTOUT DIMENSIONS

F. WIDTH

G. DEPTH

H. HEIGHT

MODEL

MINIMUM

MAXIMUM

MINIMUM

MAXIMUM

BELOW COOKTOP

30" Gas Cooktop

27 ¼ (69,2)

28 ½ (72,4)

19 

1

/

(48,6)

19 ¾ (50,2)

8 (20,3)

36" Gas Cooktop

33 

7

/

(86,1)

34 ¼ (87)

19 

1

/

(48,6)

19 ¾ (50,2)

8 (20,3)

Summary of Contents for EW30GC55PB1

Page 1: ...r building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency orthe gas supplier All dimensions are stated in inches and cm Dimension H includes a 5 12 7 cm space underneath the cooktop for connection to gas...

Page 2: ... Care Guide read it carefully Air curtain or other overhead hoods which operate by blowing a downward air flow on to a range shall not be used in conjunction with gas ranges other than when the hood and range have been designed tested and listen by an independent test laboratory for use in combination with each other Be sure your cooktop is installed and grounded properly by a qualified installer ...

Page 3: ...Edge of Cutout and Nearest Combustible Surface Above Countertop 18 Min 45 7 cm Clearance 30 76 2 cm Min Clearance Between the Top of the Cooking Platform and Unprotected Wood or Metal Cabinet 24 61 cm 13 33 cm Max Depth For Cabinet Installed Above Cooktop C C Allow a minimum of 6 16 5 cm below the countertop for drawer Make sure there will be no interference with gas or electrical connection MODEL...

Page 4: ...djoining cabinets Panel height should allow for installation of approved cooktop models See Typical Gas Cooktop Installation Over an Electric Built in Oven Installed Under the Counter on next page 36 91 4 cm Min Junction box must be located approx 3 7 6 cm to the left of the built in oven cutout This cooktop may be installed over certain built in electric oven models Figure 3 Use 3 4 1 9 cm plywoo...

Page 5: ...d Under the Counter GAS COOKTOP 18 45 7 cm Max 5 12 7 cm Flare Union 4 10 2 cm 120V 60Hz Grounded Outlet Right Side of Cabinet Pressure Regulator Flare Union Flexible Connector Cabinet sides or filler panel 6 16 5 cm Min Manifold Pipe Manual Shutoff Valve To be accessible for shut off valve operation Figure 4 Cooktop Wall Oven Side view Front view ...

Page 6: ...ith natural gas A kit for converting to LP gas is supplied with your cooktop The kit is marked FOR LP PROPANE GAS CONVERSION The conversion must be performed by a qualified service technician in accordance with the kit instructions and all local codes and requirements Failure to follow instructions could result in serious injury or property damage The qualified agency performing this work assumes ...

Page 7: ...he power cord of this appliance is equipped with a 3 prong grounding plug which mates with a standard 3 prong grounding wall receptacle see Figure 9 to minimize the possibility of electric shock hazard from the appliance The wall receptacle and circuit should be checked by a qualified electrician to make sure the receptacle is properly grounded Where a standard 2 prong wall receptacle is installed...

Page 8: ...Cap Lip Correct Burner Cap Placement Fig 12 Incorrect Burner Cap Placement Fig 13 note that the burner heads are secured to the cooktop The cooktop is not removable Do not attempt to remove or lift the cooktop To prevent flare ups and avoid creation of harmful by products do not use the cooktop without all burner caps properly installed to insure proper ignition and gas flame size Always keep the ...

Page 9: ...Note There are no burner adjustments necessary on this cooktop 4 Adjust the LOW Setting of Surface Burner Valves linear flow Test to verify if LOW setting should be adjusted a Push in and turn control to LITE until burner ignites b Push in and quickly turn knob to lowest position c If burner goes out reset control to OFF d Remove the surface burner control knob e Insert a thin bladed screwdriver i...

Page 10: ...ico no utilice ningún aparato telefónico en su edificio Llame inmediatamente el abastecedor de gas desde el teléfono de un vecino Siga las instrucciones del abastecedor de gas En caso que no puede contactar el abastecedor de gas llame al departamento de bomberos La instalación y el servicio telefónico deben ser realizados por un instalador calificado por un servicio técnico certificado o por el ab...

Page 11: ...MPORTANTES La instalación de esta plancha de cocinar debe realizarse en conformidad con los códigos locales o si estos no existen con el National Fuel Gas Code ANSI Z223 1 NFPA 54 en los Estados Unidos o en Canada con el Canadian Fuel Gas Code CAN CGA B149 y CAN CGA B149 2 La instalación de aparatos diseñados para instalación en casas prefabricadas móviles debe conformar con el Maufactured Home Co...

Page 12: ...e posterior del hueco y la más cerca superficie combustible por encima del mostrador 18 Min 45 7 cm Espacio 24 61 cm C C Máx profundidad de gabinetes instalados por encima de la plancha de empotar es 13 33 cm 30 76 2 cm Mínimo de espacio entre la parte superior de la plataforma de la plancha de cocinar y el fondo de una madera non protegida o armario metálico 6 16 5 cm mínimo de espacio para utili...

Page 13: ...s fijaciones de montaje deben de estar utilizadas para sujetar el horno empotrado a los armarios Refiere a las instrucciones de instalación del horno empotrado Entrepaños llenador de lados son necesarios para aislar el aparato de los armarios adyacentes La altura de panel debe de permitir la instalación de modelos de planchas de cocinar aprobantes Ver Instalación típica de plancha de cocinar a gas...

Page 14: ...ador PLANCHA DE COCINAR 18 45 7 cm Máx 5 12 7 cm Unión 4 10 2 cm Unión 120V 60Hz Toma de corriente a tierra Lado derecho del armario Regulador de presión Unión Conector flexible Cabinet sides or filler panel 6 13 5 cm Mín Tubo múltiple Válvula de cierre manual Debe de ser accesible para el funciona miento de la válvula de cierre Figura 4 Cooktop Wall Oven Side view Front view ESTUFA DE GAS Vista d...

Page 15: ... como se indica Monte el conector flexible del tubo del suministro de gas al regulador de presión en funcionamiento 1 válvula de cierre manual 2 boquilla de 1 2 1 3 cm 3 adaptor de 1 2 1 3 cm 4 conector flexible 5 adaptator de 1 2 1 3 cm 6 boquilla de 1 2 1 3 cm 7 regulador de presión Utilice un compuesto de tubo articulado para uso de gas natural y propano para sellar todas las conexiones de gas ...

Page 16: ...tector de fugas líquidas o agua y jabón en todas las articulaciones y conexiones para verificar si existen fugas No use ningún tipo de llama para verificar si hay fugas de gas Verifique si hay fugas con una llama puede ocasionar incendio o explosión Ajuste todas las conexiones en caso que sea necesario para evitar fugas de gas en la cocina o en el tubo de suministro de gas Verifique la alineación ...

Page 17: ...ente en su lugar en las cabezas redondas de los quemadores Asegúrese de que todas las tapas ovaladas de los quemadores estén colocados correctamente en su lugar en las cabezas ovaladas de los quemadores si vienen equipados Asegúrese de que todas las tapas dobles de los quemadores estén colocados correctamente en su lugar en las cabezas dobles de los quemadores si vienen equipados En los quemadores...

Page 18: ...ea Pruebe el ajuste LOW bajo para comprobar si debe ser ajustado a Oprima la perilla hacia adentro y gírela a la posición LITE encender hasta que el quemador se encienda b Oprima la perilla hacia adentro y rápidamente gírela al ajuste mínimo c Si el quemador se apaga gire la perilla a la posición OFF apagado d Retire la perilla del quemador superior e Introduzca un destornillador delgado en la var...

Page 19: ...WIRING DIAGRAM SCHÉMA DE CÂBLAGE DIAGRAMA DE LA INSTALACIÓN ALÁMBRICA 36 Gas Cooktop Table de cuisson à gaz 36 Plancha de cocinar a gas modelos de 36 pulgadas 28 A01705106 REV A A01705106 REV A ...

Reviews: