Installation Information
2-5
Clearance Requirements
Installation in a Recess or Closet
If washer and dryer are installed in the same closet,
door ventilation is required: A minimum of 120 square
inches (774.2 cm²) of opening, equally divided at the top
and bottom of the door, is required. Louvered openings
should be located 3 inches (7.6 cm) from bottom and top
of door. Air openings are required to be unobstructed
when a door is installed. A louvered door with equivalent
air openings for the full length of door is acceptable.
Figure 2-4. Closet Installation
Figure 2-5. Clearances
DO NOT INSTALL THE WASHER:
1. In an area exposed to dripping water or outside
weather conditions. The ambient temperature
should never be below 60°F (15.6° C) to
maximize detergent effectiveness.
2. In an area (garage or garage-type building)
where gasoline or other flammables (including
automobiles) are kept or stored.
3. Floor MUST be solid with a maximum slope
of 1 inch (2.54 cm). To minimize vibration or
movement, reinforcement of the floor may be
necessary.
Summary of Contents for EIFLW55H MB
Page 2: ......
Page 14: ...1 12 Basic Information Notes ...
Page 20: ...Installation Information 2 6 Installed Washer Dimensions ...
Page 36: ...Installation Information 2 22 Notes ...
Page 38: ...Electronic Control 3 2 Wave Touch Washer Cycle Chart ...
Page 40: ...Electronic Control 3 4 IQ Touch Washer Cycle Chart ...
Page 57: ...Electronic Control 3 21 Error Code Chart ...
Page 58: ...Electronic Control 3 22 Error Code Test Chart ...
Page 59: ...Electronic Control 3 23 Error Code Test Chart ...
Page 60: ...Electronic Control 3 24 Notes ...
Page 82: ...Component Teardown 4 22 Notes ...
Page 88: ...Troubleshooting 5 6 Notes ...
Page 89: ...Wiring Schematics 6 1 Model EWFLW65H EIFLW55H ...
Page 90: ...Wiring Schematics 6 2 Notes ...