background image

Gas hobs

Mod. EHG 673 - EHG 691

INSTRUCTION  BOOKLET

Please read this instruction booklet before using the appliance

35675-8203

GB

Summary of Contents for EHG 673

Page 1: ...Gas hobs Mod EHG 673 EHG 691 INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance 35675 8203 GB ...

Page 2: ...b is intended for domestic cooking only It is not designed for commercial or industrial purposes l When in use a gas cooking appliance will produce heat and moisture in the room in which it has been installed Ensure there is a continuous air supply keeping air vents in good condition or installing a cooker hood with a venting hose l When using the hob for a long period of time the ventilation shou...

Page 3: ...onditions 6 Instructions for the Installer 7 Engineers technical data 7 Important Safety Requirements 8 Installation 8 Building In 9 Electrical connections 10 Wiring Diagram 11 Fault Finding 11 Commissioning 13 Conversion from Natural Gas to LPG 14 Description of the Hobs 1 Hob Top 2 Rapid Burner 3 Semi rapid Burners 4 Auxiliary Burner 5 Control knobs 6 Electric Ignition Push Button 1 3 2 4 3 5 EH...

Page 4: ... the hob top using a soft cloth well wrungoutinwarmwatertowhichalittlewashingupliquid has been added Avoid the use of the following household detergent and bleaches impregnated pads unsuitable for non stick saucepans steel wool pads bath sink stain removers F Should the hob top become heavily soiled the following products are recommended For stainless steel hobs use a proprietary stainless steel c...

Page 5: ...ice Force Centre Please note that it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown In the event of your appliance requiring service or if you wish to purchase spare parts please contact your local E...

Page 6: ...which are the subject to rental agreements Products of Electrolux manufacture which are not marketed by Electrolux European Guarantee If you should move to another country within Europe then your guarantee moves with you to your new home subject to the following qualifications The guarantee starts from the date you first purchased your product The guarantee is for the same period and to the same e...

Page 7: ...able plug fitted with a 3 amp cartridge fuse Instructions for the Installer Engineers technical data BURNER RAPID SEMI RAPID AUXILIARY large medium small POSITION MAX MIN MAX MIN MAX MIN NOMINALTHERMAL 3 0 0 65 2 0 0 45 1 0 0 33 POWER kW NOMINALFLOW 0 286 0 062 0 190 0 043 0 095 0 031 RATE m3 h NOZZLEREFERENCE 119 Adjust 96 Adjust 70 Adjust 1 100 mm NOMINALTHERMAL 2 8 0 65 2 0 0 45 1 0 0 33 POWER ...

Page 8: ... room but not in a bathroom shower room or garage Before making the cut out in the worktop ensure that the edges of the hob that are to be near either a side or rear wall have a minimum distance of 55 mm between the edge of the hob and the wall The minimum distance combustible material can be fitted above the hob is 400 mm If it is fitted below 400 mm a space of 50 mm must be allowed from the edge...

Page 9: ...e to allow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections Rectangular cut out size for hob A End of shaft with nut B Washer C Elbow It is important to install the elbow correctly with the shoulder on the end of the thread fitted to the hob connecting pipe Failure to ensure the correct assembly will cause leakage of gas FO 0814 Gas Conn...

Page 10: ... need to be replaced for any reason the wires in the mains lead are coloured in accordance with the following code Green and Yellow Earth Blue Neutral Brown Live Connect the green and yellow earth wire to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green and yellow Connect the blue neutral wire to the terminal in the plug which is marked with the lett...

Page 11: ...ss than infinity there is a fault NOTE Should it be found that the fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty component It is possible that a fault could occur as a result of local burning arcing but no fault could be found under test However a detailed visual inspection should reveal eviden...

Page 12: ...Light burner manually Check gas supply at burner Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check for breaks in the insula...

Page 13: ...nite the burner and set to MIN Remove the control knob To adjust use a thin bladed screwdriver and turn the adjustment screw see diagram until the flame is steady and does not extinguish when the knob is turned from MIN to MAX Repeat this procedure for all burners Pressure Testing Remove left hand pan support and front left burner cap and crown Fit manometer tube over the injector Turn on the burn...

Page 14: ...ob from the electrical supply Remove all pan supports burner caps rings crowns and control knobs With the aid of a 7mm box spanner the burner injectors can then be unscrewed and replaced by the appropriate LPG injectors To adjust the gas rate With the aid of a thin bladed screwdriver completely tighten down the by pass adjustment screw Upon completion affix the replacement rating plate on the unde...

Page 15: ...15 ...

Page 16: ...No 1 choice The Electrolux Group is the world s largest producer of powered appliances for kitchen cleaning and outdoor use More than 55 million Electrolux Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world ...

Reviews: