background image

11

A. IGNITOR SWITCH

B. IGNITOR UNIT

1

2

L

N

0

220
240

1

2

3

4

Wiring Diagram

Fault Finding

Preliminary Electrical Systems

Check

A. EARTH CONTINUITY CHECK

 - Appliance must be

electrically disconnected - meter set on 

W

 (Ohms) x

1 scale and adjust zero if necessary.

a) Test leads from any appliance earth point to earth

pin on plug. Resistance should be less than 0.1

W

 (Ohm), check all earth wires for continuity and

all contacts are clean and tight.

B.  INSULATION  CHECK

  - Appliance  electrically

disconnected,  all  switches  ON.

a) meter set on 

(Ohms) x 1 scale.

Test leads from L to N in appliance terminal block.

If meter reads «0» then there is a short circuit.

b) meter set on 

W

 (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads

less than 

¥

 (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed

but no fault is indicated - a detailed continuity check

(i.e.  by  disconnecting  and  checking  each

component) is required to trace the faulty component.

It is possible that a fault could occur as a result of

local burning/arcing but no fault could be found under

test.  However  a  detailed  visual  inspection  should

reveal evidence of burning around the fault.

START

Isolate appliance

and carry out:

A:

 Earth Continuity

check.

 Has inlet fuse blown?

Carry out:

C:

 Polarity check.

Electricity supply

should now be

satisfactory.

Carry out:

D:

 Resistance to

Earth check.

Inlet wiring

faulty.

Rectify any

fault.

Isolate appliance and

carry out:

B:

 Insulation check.

Rectify any fault

including replacing

fuses as necessary.

SOCKET

(face  view)

PLUG  (with  cover

removed)

Earth Wire

Green/Yellow

Neutral Wire

Blue

Brown

Blue

Green

Yellow

Green

Yellow

Brown

Blue

(   )

FUSE

(   )

E

N

L

NO

YES

NO

YES

Summary of Contents for EGG 689

Page 1: ...Gas hob Mod EGG 689 INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance 35678 9001 GB ...

Page 2: ...at and moisture in the room in which it has been installed Ensure there is a continuous air supply keeping air vents in good condition or installing a cooker hood with a venting hose l When using the hob for a long period of time the ventilation should be improved by opening a window or increasing the extractor speed l Do not use this hob if it is in contact with water Do not operate the hob with ...

Page 3: ...ce and Spare Parts 5 Guarantee Conditions 6 Instructions for the Installer 7 Important safety requirements 8 Installation 8 Building In 9 Electrical connections 10 Wiring Diagram 11 Fault Finding 11 Commissioning 13 Conversion from Natural Gas to LPG 14 Description of the Hob 1 Hob top 2 Rapid Burner 3 Semi rapid Burner 4 Auxiliary Burner 5 Control knobs 1 3 5 2 3 4 ...

Page 4: ...luminiumframe using a soft cloth well wrung out in warm water to which a little washing up liquid has been added Avoid the use ofthefollowing household detergent and bleaches impregnated pads unsuitable for non stick saucepans steel wool pads bath sink stain removers Should the hob top become heavily soiled it is recommendedthatacleaningproductsuchasHobBrite or Bar Keepers Friend is used Pan Suppo...

Page 5: ...ice Force Centre Please note that it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown In the event of your appliance requiring service or if you wish to purchase spare parts please contact your local E...

Page 6: ...urs in which case a premium will be charged Exclusions This guarantee does not cover Damage or calls resulting from transportation improper use or neglect the replacement of any light bulbs or removable parts of glass or plastic Costs incurred for calls to put right an appliance which is improperly installed or calls to appliance outside the United Kingdom Appliances found to be in use within a co...

Page 7: ...ra Control s BF 50046 230 240V 0 6 YA T 120 Spark Gap Fixed Semi rapid Burner Heat Input 1 9 kW 6483 BTU HR Rapid Burner Heat Input 2 9 kW Natural Gas 9895 BTU HR 2 7 kW L P G 9212 BTU HR Auxiliary Burner Heat Input 1 0 kW 3412 BTU HR BURNER RAPID SEMI RAPID AUXILIARY large medium small POSITION MAX MIN MAX MIN MAX MIN NOMINALTHERMAL POWER kW 2 9 0 65 1 9 0 45 1 0 0 33 NOMINALFLOW RATE m3 h 0 276 ...

Page 8: ...l can be fitted above the hob is 400 mm If it is fitted below 400 mm a space of 50 mm must be allowed from the edges of the hob The minimum distance combustible material can be fitted directly above the hob is 700 mm Aminimum distance of 100 mm must be left between the side edges of the hob and any adjacent cabinets or walls Installation IMPORTANT This hob must be installed by qualified personnel ...

Page 9: ... operated The recommended solution is shown in diagram 3 The panel fitted under the hob a should be easily removable to allow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections Fitting the hob to the worktop Before fitting the hob into the cut out an adhesive seal must be fitted to the underside outside edge diagram 4 of the hob It is esse...

Page 10: ...th the letter E or the earth symbol or coloured green and yellow Connect the blue neutral wire to the terminal in the plug which is marked with the letter N or coloured black Connect the brown live wire to the terminal in the plug which is marked with the letter L or coloured red Upon completion there must be no cut or stray strands of wire present and the cord clamp must be secure over the outer ...

Page 11: ... than infinity there is a fault NOTE Should it be found that the fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty component It is possible that a fault could occur as a result of local burning arcing but no fault could be found under test However a detailed visual inspection should reveal evidence...

Page 12: ...Light burner manually Check gas supply at burner Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check for breaks in the insula...

Page 13: ...nite the burner and set to MIN Remove the control knob To adjust use a thin bladed screwdriver and turn the adjustment screw see diagram until the flame is steady and does not extinguish when the knob is turned from MIN to MAX Repeat this procedure for all burners PressureTesting Remove left hand pan support and front left burner cap and crown Fit manometer tube over the injector Turn on the burne...

Page 14: ...ob from the electrical supply Remove all pan supports burner caps rings crowns and control knobs With the aid of a 7mm box spanner the burner injectors can then be unscrewed and replaced by the appropriate LPG injectors To adjust the gas rate With the aid of a thin bladed screwdriver completely tighten down the by pass adjustment screw Upon completion affix the replacement rating plate on the unde...

Page 15: ...15 ...

Page 16: ... s No 1 choice The Electrolux Group is the world s largest producer of powered appliances for kitchen cleaning and outdoor use More than 55 million Electrolux Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world ...

Reviews: