BURNER
NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Semi-rapid
1,9
0,45
96
Auxiliary
1,0
0,33
70
9.5 Gas burners for LPG G30/G31 30/30 mbar
BURNER
NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS
FLOW g/h
Rapid
2,7
0,75
86
196
Semi-rapid
1,9
0,45
71
138
Auxiliary
1,0
0,33
50
73
9.6 Electric cooking zones specification
Cooking zone Nominal Power (Max heat set‐
ting) [W]
Cooking zone diameter [mm]
Left rear
1800
180
For optimal cooking results use
cookware not larger than the diameter of
the cooking zone.
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification
EGE6182NOK
Type of hob
Built-in hob
Number of electric cooking zones
1
Heating technology per electric
cooking zone
Radiant Heater
Diameter of circular electric cook‐
ing zones (Ø)
Left rear
18.0 cm
Energy consumption per cooking
zone (EC electric cooking)
Left rear
180.2 Wh / kg
Number of gas burners
3
www.electrolux.com
32