9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Triple
Crown
3,8
1,4
98
276
271
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification
EGC3313NOK
Type of hob
Built-in hob
Number of gas burners
1
Energy efficiency per gas burner
(EE gas burner)
Centre middle - Triple Crown
54.3%
Energy efficiency for the gas hob
(EE gas hob)
54.3%
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of
energy - General
10.2 Energy saving
• Before use, make sure that the burners and pan supports are assembled correctly.
• Use cookware with diameters applicable to the size of burners.
• Center the pot on the burner.
• When you heat up water, use only the amount you need.
• If it is possible, always put the lids on the cookware.
• When the liquid starts to boil, turn down the flame to barely simmer the liquid.
• If it is possible, use a pressure cooker. Refer to its user manual.
11. ENVIRONMENT CONCERNS
Please recycle all materials marked with
the symbol . Dispose of all packaging
materials appropriately and help to
protect the environment, and future
generations. Do not dispose of electrical
equipment marked with the symbol
along with the general house hold waste.
Dispose all electrical goods via
applicable local authority collections, or
at local authority or, commercial recycling
centres.
*