EFC 9542
Instructions Manual
Manual de instrucciones
Manual de Instruções
Page 1: ...EFC 9542 Instructions Manual Manual de instrucciones Manual de Instruções ...
Page 2: ...EN 2 2 Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS 5 CHARACTERISTICS 6 INSTALLATION 7 USE 10 MAINTENANCE 12 ...
Page 3: ...ES 3 3 Manual de instrucciones ÍNDICE CONSEJOS Y SUGERENCIAS 14 CARACTERÍSTICAS 15 INSTALACIÓN 16 USO 19 MANTENIMIENTO 21 ...
Page 4: ...PT 4 4 Manual de Instruções ÍNDICE CONSELHOS E SUGESTÕES 23 CARACTERÍSTICAS 24 INSTALAÇÃO 25 UTILIZAÇÃO 28 MANUTENÇÃO 30 ...
Page 5: ...of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has ben de signed Never leave high n...
Page 6: ...ion 2 2 1 Lower Section 9 1 Reducer Flange ø 150 120 mm 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 7 3 1 Air Outlet Connection Support 11 6 Wall Plugs 12a 6 Screws 4 2 x 44 4 12c 6 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction Manual 2 1 2 2 2 12c 12a 7 2 1 11 11 12a 9 7 3 14 1 15 1 1 ...
Page 7: ... chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as indicated at 116 mm from the vertical reference line and 330 mm above the horizontal reference line Repeat this operation on the other side Drill ø 8 mm holes at all the centre points marked Insert the wall plugs 11 in the holes Fix the lower...
Page 8: ...aust connection insert the re ducer flange 9 on the hood body outlet Fix the pipe in position using sufficient pipe clamps not sup plied Remove any activated charcoal filters 9 ø120 ø150 RECIRCULATION VERSION AIR OUTLET Put connection 15 into the connection support 7 3 Insert the connection extension pieces laterally 14 1 in connec tion 15 Make sure that the outlet of the extension pieces 14 1 is ...
Page 9: ...den the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12c 2 9 x 9 5 supplied Make sure that the outlet of the extensions pieces is aligned with the chimney outlets Lower exhaust flue Slightly widen the two sides of the flue and hook them between the upper flue and the wall making sure th...
Page 10: ...t Courtesy light on Touch control lit Motor on T1 When pressed the motor is stopped regardless of the speed it is set to Touch control unlit Motor off T2 When pressed the motor is set to the first speed Touch control lit By a brief pressing the motor is set to the second speed Touch control lit Second speed on T3 By pressing the touch control for approximately 2 seconds the Delay function is enabl...
Page 11: ... intensive speed Touch control lit Touch control lit Metal grease filters satu ration alarm Metal grease filters need to be washed The alarm starts up after 100 working hours F When pressed for 4 seconds it resets the filter alarm signal indicated by flashing of the touch control T1 This procedure can be carried out only when the motor is stopped Flashing touch control Charcoal odour filter satu r...
Page 12: ...y 2 months or even more frequently in case of particularly intensive use of the hood Remove the filters one by one pushing them towards the back side of the unit and simultaneously pulling downwards Any kind of bending of the filters has to be avoided when washing them Before fitting them again into the hood make sure that they are completely dry When fitting the filters into the hood pay attentio...
Page 13: ...ss the touch control F until the key itself flashes to confirm as follows 2 flashes Charcoal odour Filter saturation Alarm ENABLED 1 flash Charcoal odour Filter saturation Alarm DISABLED REPLACING THE CHARCOAL ODOUR FILTER Reset the alarm signal Stop the motor Press the touch control F for at least 4 seconds until the touch control T1 flashes Replace the Filter Remove the metal grease filters Remo...
Page 14: ...arse de que este producto se deseche correctamente usted ayudará a evitar posibles consecuencias negativas para el ambiente y la salud pública lo cual podría ocurrir si este producto no se manipula de forma adecuada Para obtener información más detallada sobre el reciclaje de este producto póngase en contacto con la administración de su ciudad con su servicio de desechos del hogar o con la tienda ...