7
GB
Mounting the hood body
• Before attaching the hood body, tighten the two
screws
Vr
located on the hood body mounting
points.
• Hook the hood body onto the screws
12a
• Fully tighten support screws
12a
• Adjust screws
Vr
to level the hood body.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid
pipe ø 150 or 120 mm, the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection,
insert the reducer flange
9
on the hood body
outlet.
• Fix the pipe in position using sufficient pipe
clamps (not supplied).
• Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
• Put connection
15
into the connection support
7.3.
• Insert the connection extension pieces laterally
14.1
in connection
15.
• Make sure that the outlet of the extension pieces
14.1
is horizontally and vertically aligned with the
chimney outlets.
• Connect the air outlet connection
15
to the hood
body outlet using either a flexible or rigid pipe ø 150
mm, the choice of which is left to the installer.
• Ensure that the activated charcoal filters have been
inserted.
12a
Vr
9
ø 120
ø 150
ø 150
14.1
15
Summary of Contents for EFC 1540