Operation test
Perform test operation after completing gas leak check at the flare nut
connections and electrical safety check.
1. Connect the power, press the
ON/OFF button on the remote
controller to turn the unit on.
2. Use the MODE button to select
COOL, HEAT, AUTO and FAN to
check if all the functions works
well.
3. When the ambient temperature is
too low(lower than 17ºC), the unit
cannot be controlled by the remote
controller to run at cooling mode,
manual operation can be taken.
Manual operation is used only when
the remote controller is disable or
maintenance necessary.
29 electrolux
operation test
1. Contact a specialist to install the device.
2. Guarantee that the unit is appropriately fastened and complies with all of
the aforementioned safety norms.
3. Before operating the air conditioner, ensure that the air filter is installed
correctly.
4. If the unit has been out of use for a long period of time, it is recommended
that the air filter be cleaned before use. During continuous use, clean the air
filter every two weeks.
5. This air conditioner was designed for use under the following conditions:
If air conditioner is used outside of the above conditions, certain safety protection
features may come into operation and cause the unit to function abnormally.
Room relative humidity less than 80%. If the air conditioner operates in excess of
this figure, the surface of the air conditioner may attract condensation. Please
sets the vertical air flow louver to its maximum angle (vertically to the floor), and
set HIGH fan mode.
Optimum performance will be achieved within these operating temperature.
Preparing the device for operation
preparing the device for operation
electrolux 30
Manual control button
Auto/Cool
Manual control
button
Auto
Cool
or
* (-5°C~43°C cooling only)
Cool
Heat
Deshumidifier
MODE
Room Temperature
Room Temperature
Room Temperature
Indoor
Outdoor*
Indoor
Outdoor
Indoor
Outdoor
17°C~32°C 18°C~43°C 17°C~30°C -7°C~24°C 17°C~32°C 11°C~43°C