19
Hints for test centres
Before starting any test it is necessary to fill completely with salt the salt container and with rinse aid the rinse
aid dispenser.
IST40en
Test standard
EN 50242
Reference programme:
Bio Wash
Load:
8 standard place settings
Rinse aid selector:
position 4
Detergent dosage :
20 g in the dispenser
5 g on the dispenser lid
UI57
US62
Arrangement
upper basket
Arrangement
lower basket
DIMENSIONS
Width
45 cm
Height with worktop
85 cm
Height without worktop
82 cm
Max depth
60 cm
Max depth with open door
115.9 cm
ELECTRICAL CONNECTION
Voltage
220/240 V - 50 Hz
MOTOR RATING DURING WASH
200 W
POWER OF HEATING ELEMENT
2570 W
OVERALL POWER
2770 W
WATER SUPPLY PRESSURE
Minimum
50 kPa (0.5 bar)
Maximum
800 kPa (8 bar)
CAPACITY
8 place settings
Technical specifications