To set the cycle proceed as follows:
• Set the cavity temperature (A);
• Set the core probe temperature or the time (B);
• Touch
button to start the cycle;
If the cavity temperature is lower or higher then the set
temperature the oven starts a cooling or a preheating phase.
• Once the set cavity temperature is reached, load the food into
the oven and the food core probe into the product.
At the end of the cycle the display shows the consumptions (if
available) as a recap message.
It is possible to save and store the performed presets; see how to
manage them at
paragraph of this chapter.
F.7
Programs mode
The “Programs Mode“ allows to recall program recipes already
stored or create and store new ones.
1. Select Programs mode. The display shows all stored
programs.
(To change the programs displaying see F.15
chapter
⇨
Programs mode
⇨
grid visualization).
2. Touch the required program;
The oven loads the program in Manual mode ready to be
launched.
How to create and save a program
• Select a cycle in Manual mode (see F.5
chapter);
• If necessary modify the cooking parameters according to your
requirement;
• Open the lower drawer and touch the relevant icon to save the
programme;
• Edit the program name on the appearing keypad and confirm.
The new program will be stored in Programs mode.
How to manage stored programs
1. Touch the 3 dots near the program icon to access the
“features management“ menu;
CHANGE IMAGE
Low temper.
cooking
Eco Delta
cooking
Regeneration
Proving
Sous vide
Advance FSC
FSC low risk
guide
FSC high risk
guide
Dehydratating
Fresh pasta
pastorization
Smoker
Static combi
AUTOMATIC
USER
100
10
25
4
°C
°C
°C
USER
PRESET 1
A
B
1
01:20 h:m
0 120
:
:00
160°C
50%
20
%
25
°C
?
Manual
Automatic
Prog rams
Custom
Cleaning
Settings
Help
User
Agenda
Plan &
save
Prog ram’s
name 1
Prog ram’s
name 2
Prog ram’s
name 3
Prog ram’s
name 5
Prog ram’s
name 6
Prog ram’s
name 7
Prog ram’s
name 8
Prog ram’s
name 9
Prog ram’s
name 10
Prog ram’s
name 11
Prog ram’s
name 12
Prog ram’s
name 4
All p rog rams
PROGRAM S
USER
100
%
0030
:
:00
00:30 h:m
160°C
PM
5:30
100%
120°C
300°C
Delayed
start
Save
program
Fan
speed
7
Water
injection
Half
power
Food
Safe
Control
MANUAL
USER
FSC
Z
A
Q W E R T Y U I O P
1 2 3 4 5 6 7 8 9 0
S D F G
Space
H J K L
X C V B N M
#+,
NEW PROGRAM’S NAME
2
3
1
00:30
:00
160°C
01:30 h:m
100
°C
New program
1
Program 5
New program
All programs
PROGRAMS
2
20
%
Program’s
name 1
Program’s
name 2
Program’s
name 3
Program’s
name 5
Program’s
name 6
Program’s
name 7
Program’s
name 8
Program’s
name 9
Program’s
name 10
Program’s
name 11
Program’s
name 12
Program’s
name 4
All programs
PROGRAMS
USER
Program’s
name 1
Program’s
name 2
Program’s
name 3
Program’s
name 5
Program’s
name 6
Program’s
name 7
Program’s
name 8
Program’s
name 9
Program’s
name 10
Program’s
name 11
Program’s
name 12
Program’s
name 4
All programs
PROGRAMS
USER
Abc