1
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
H
B
C
F
G
E
D
A
2½” (6.4 cm)
30” Min*
(76.2 cm)
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
WARNING
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
Cooktop Dimensions
IMPORTANT INSTALLATION-INFORMATION
• All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60 hertz, AC only
electrical supply with ground.
• Please note minimum distances between cooktop and overhead cabinets is 30" (76.2 cm).
* 30" (76.2 cm) min. for unprotected cabinet
24" (61 cm) min. for protected surface
Cooktop Cutout Dimensions
All dimensions are in inches (cm).
* Allow 2" (5.1 cm) space below cooktop to clear the electric cable and allow for
installation of the junction box on the wall at the back of the cooktop.
Printed in United States
P/N 318201423 (0506) Rev. A
English – pages 1-6
Español – pages 7-12
Figure 1
PRODUCT DIMENSIONS
MODEL
A
. LENGTH
B
. WIDTH
C
. DEPTH
D
. BOX LENGTH
E
. BOX WIDTH
30" Coil Elements
30 (76.2)
21¾ (55.2)
4½ (11.4)
27 (68.6)
19 (48.3)
36" Coil Elements
36 (91.4)
21¾ (55.2)
4½ (11.4)
33¼ (84.5)
19 (48.3)
CUT OUT DIMENSIONS
F
. LENGTH
G
. WIDTH
H
. DEPTH BELOW
MODEL
MINIMUM
MAXIMUM
MINIMUM
MAXIMUM
COOKTOP*
30" Coil Elements
27¼ (69.2)
28½ (72.4)
19
1
/
8
(48.6)
19¾
(50.2)
7 (17.8)
36" Coil Elements
33
7
/
8
(86)
34¼ (87)
19
1
/
8
(48.6)
19¾ (50.2)
7 (17.8)