Installation manual
When the installation is completed remount the cover panel and check:
• That the drum is empty.
• That the machine operates by connecting the power to the machine and start a program with heat.
5.5
Electrical connections
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended fuse
A
Electric heated
machines
220–230V 3 ~
50/60
18.0
19.0
50
240V 3 ~
50/60
18.0
19.0
50
380–415V 3N ~
50/60
18.0
19.0
32
440V 3 ~
50/60
18.0
19.0
32
480V 3 ~
60
18.0
19.0
25
Gas- and Steam
heated machines
220–240V 3 ~
50/60
*
1.0
10
380–415V 3N ~
50/60
*
1.0
10
440V 3 ~
50/60
*
1.0
10
480V 3 ~
60
*
1.0
10
Machines with heat
pump
220–240V 1 ~ / 1N ~
50/60
*
5.5
25
380–480V 3 ~ / 3N ~
50/60
*
6.5
10
* Total power and recommended fuse does not depend on the heating power in those cases.
6 Steam connection
6.1
Connecting the steam
The steam supply must be cut off and must not be under pressure.
Steam inlet
• The branch pipes must be located at the top of the main steam pipe to prevent condensation in the steam.
• The branch pipe must have a descending gradient and must end at a height above the inlet connecting branch (5).
• Mount a plug valve (A) and a strainer (B) in the branch pipe.
• If the branch pipes are too far away from the main pipe, to maintain quality of the steam, it is recommended to in-
stall a steam trap (F).
5
6
A
B
D
E
C
F
fig.7194B