6
Installation manual
3 Note about the A.C. power
According to the EN 60204-1:1997 standard, the machine is provided for A.C. supplies corresponding to the ex-
tracted characteristics below :
4.3.2 A.C. supplies
Voltage:
Steady state voltage: from 0.9 to 1.1 of nominal voltage.
Frequency:
from 0.99 to 1.01 of nominal frequency continuously.
from 0.98 to 1.02 short time.
Harmonics:
Harmonic distortion not to exceed 10 % of the total r.m.s. voltage between live conductors for the sum of the second
through to the fifth harmonic. An additional 2 % of the total r.m.s. voltage between live conductors for the sum of the
sixth through to the 30th harmonic is permissible.
Voltage unbalance:
Neither the voltage of the negative sequence component nor the voltage of the zero sequence component in three-
phase supplies shall exceed 2 % of the positive sequence component.
Voltage interruption:
Supply interrupted or at zero voltage for not more than 3 ms at any random time in the supply cycle. There shall be
more than 1 second between successive interruptions.
Voltage dips:
Voltage dips shall not exceed 20 % of the peak voltage of the supply for more than one cycle. There shall be more
than 1 second between successive dips.
4 Packaging-Weight
The ironing machine is secured to a transport pallet and packaged in a cardboard box.
Ironing width
Units
1 m
1.4 m
1.6 m
Packaging dimensions (boxed)
Length (A)
mm
1480
1880
2130
Width (B)
mm
540
540
540
Height (C)
mm
1150
1150
1150
Weight
kg
138
165
185
Summary of Contents for IB42310
Page 1: ...Installation manual Ironers IB42310 IB42314 IB42316 Originals instructions 05405004 EN ...
Page 2: ......
Page 4: ......
Page 20: ...20 Installation manual 15Annexes 15 1 Control diagram printed circuit ...
Page 23: ......
Page 24: ...Share more of our thinking at www electroluxprofessional com ...