![Electrolux Professional Compass Pro TD6-10 Installation Manual Download Page 26](http://html.mh-extra.com/html/electrolux-professional/compass-pro-td6-10/compass-pro-td6-10_installation-manual_2385598026.webp)
26
Installation manual
Town gas
Gas category
Inlet pressure
(mbar)
Injector pres-
sure (mbar)
Injector size (
⌀
mm)
Air reducing
plate (mm)
Label number
May be avail-
able in follow-
ing countries
1a
8
4.5
4.45
487042240
Default
DK, IT
1b
8
3.5
4.45
487042240
490376103
SE
7.5
Test run
• Loosen the measuring branch screw (2) 1/4 turn; connect a manometer to the measuring branch.
• Select a program with heat.
• Start the machine.
• Check the nozzle pressure, see “Table of pressure and adjustment”.
• If necessary adjust the regulator setting screw (4) behind the cover screw (3). Replace the cover screw (3) if
removed.
• Check that the gas is burning evenly. The blue flame on the burner is preferred.
2
3, 4
fig.7120
7.6
Converting instructions
• Disconnect the power to the machine.
• Demount the back panel.
• Remove the nozzle (1).
• Mount the new supplied nozzle.
1
fig.7506A