background image

                                                                                     

  

Adjusting the idling current has to be performed at normal room temperature. In case the power amplifier had
previously been operated, it has to be given several hours to cool off.

4.2. FLOATING - SYMMETRY
Immediately after setting the idle current, a symmetry check of the floating voltage has to be performed. The
power amplifier has to be operated in idling condition. DC-volt meters have to be connected between the
measuring points 1 - 2, and 2 - 3. Using the FLOATING-trim potentiometers that are located on the printed
board assembly 86207/86211, the floating voltage is set symmetric to the ground potential. Not the actual
voltage value is relevant but the symmetry of the + floating voltage and the - floating voltage to the ground
potential.

Setting

Measuring

point 1

Measuring
point 2

Measuring

point 3

U(DC)

Trim

potentiometer

FLOTING SYMMETRIE A

CNSERV 8

AMP-A

CNSERV 7

AMP-A

CNSERV 9

AMP-A

ca. 

±

 67V

VR102

FLOTING SYMMETRIE B

CNSERV 8

AMP-B

CNSERV 7

AMP-B

CNSERV 9

AMP-B

ca. 

±

 67V

VR202

4.3. VCA - OFFSET:
Rhythmically open and short-circuit the service switch S101 respectively S201 which are located on the printed
board assembly 86207/86211. Use VR101 respectively VR201 to adjust the power amplifier outputs to their
minimum offset (with oscilloscope to minimal peak value or to the audible minimal volume of the interfering
pulse).
Instead of using the service switch, it is also possible to employ the service connector with short-circuited pins
CNASERV 2 and CNASERV 3 for the power amplifier A, or short-circuited pins CNBSERV 2 and CNBSERV
3 for the power amplifier B.

4.4. ADJUSTING THE METER INSTRUMENTS

level control set all the way to its clockwise position

f = 1 kHz

Feed the signal to the inputs A or B so that the IN-LED just lights (U(E) approx. -34 dBu). Adjust the OUT-LED
to approximately the same brightness, using the trim potentiometers VR600 respectively VR601 which are
located on the printed board assembly 86207/86211.

4.5. ADJUSTING THE FANS
Close the service switch S001 on the printed board assembly 86207/86211 or insert a bridge between CNBSERV
5 and CNBSERV 6. Adjust the voltage at CNBSERV 4 to 27.5 V (DC), using the VR700. Switch the service
switch back to normal or detach the bridge.

4.6. GAIN SELECTION:
The power amplifier's input sensitivity can be set using the jumpers J11 … J13 or J21 … J23 which are located
on the printed board assembly 86207/86211. The stated values for the input sensitivity or gain are always
referenced to the level control being set to its fully clockwise position.

CHANNEL A

CHANNEL B

SELECTION

J11

J21

Input Sensitivity  0 dBu

J12

J22

Input Sensi6 dBu

J13

J23

Gain +26 dB

When shipped, the input sensitivity is set to a value of 0 dBu.

5.

Function test

5.1. OUTPUT - offset voltage
DC-voltage measuring at the loudspeaker outputs CHANNEL A/B with U(DC) 

 ±10 mV.

5.2 LIMITER

5.2.1. Attenuation test
Both channels separately driven with a 1 kHz signal up to U(A) = 89 V (without load). Increase the input voltage
by 10 dB. The LIMITER LED lights and the output voltage ascents by approx. 0.5 dB to 91 volts, with slight

Summary of Contents for Precision P3000

Page 1: ...P3000 PRECISION SERIES SERVICE MANUAL...

Page 2: ...into your outlet consult an electrican for replacement of the absolete outlet 1 Security regulations as stated in the EN 60065 VDE 0860 IEC 65 and the CSA E65 94 have to be obeyed when servicing the a...

Page 3: ...ive circuit For the so called soft start the power outputs are switched on delayed via relays An inrush current limiter circuit prevents the mains fuses from being blown Maximum precision is also guar...

Page 4: ...at our option without charge The product will be returned to the customer prepaid Exclusions and Limitations The Limited Warranty does not apply to a exterior finish or appearance b certain specific i...

Page 5: ...DIMENSIONS BLOCK DIAGRAM...

Page 6: ...annel BRIDGED 0 dBu 6 dBu 13 dBu 2400 W 8 Channel BRIDGED 2 dBu 4 dBu 11 dBu 3000 W 4 Maximum input level 21 dBu C OUTPUT PROPERTIES nominal output power with THD 0 1 20 Hz 20 kHz MBW 80 kHz maximum o...

Page 7: ...DIM 100 0 01 3 15 kHz 15 kHz J CROSSTALK at f 1 kHz less than 70 dB K DAMPING FACTOR internal at f 1 kHz 300 at f 100 Hz 400 L SLEW RATE internal 40 V s M NOISE INTERFERENCE U F external voltage un w...

Page 8: ...3 15V 3 15 V 4 Hot Out 4 GND 4 Fan voltage 5 BIAS Cold Side 5 15 V 5 Service Fan Switch 6 BIAS Cold Side 6 heat sink temperature A B 6 Service Fan Switch 7 GND 7 U1 front end A 7 U1 front end B 8 flo...

Page 9: ...ort circuited pins CNASERV 2 and CNASERV 3 for the power amplifier A or short circuited pins CNBSERV 2 and CNBSERV 3 for the power amplifier B 4 4 ADJUSTING THE METER INSTRUMENTS level control set all...

Page 10: ...en CNBSERV 5 and CNBSERV 6 allows for testing the functioning of the fans During operation CNASERV 6 can be utilized to monitor the temperature of the heat sink FAN SPEED U DC CNASERV 6 U DC CNBSERV 4...

Page 11: ...aralleled at the input Both channels can be driven using a common signal source 8 Level BRIDGED MODE set the level control all the way to its fully clockwise position HI LOW CUT switch is ON as factor...

Page 12: ...erference voltage Equivalent input interference level Residual interference output voltage U F 615 V 101 dB 6 9 V 101 dBu 435 V U G 3 65mV 85 5 dB 41 V 85 5 dBu 1 55mV U A 490 V 103 dB 5 5 V 103 dBu 3...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...KABEL NETZ BEARB AUS 348951 mains cable USA 352268 STECKER NETZ 30A UL CSA mains connector 30amp US 349846 KABEL KONFEKT 8POL 0 680M ribbon cable assy 8way 349847 KABEL KONFEKT 10POL 0 800M ribbon ca...

Page 21: ...1N 4148 AXIAL diode 1N 4148 D0002 307916 DIODZ BZX 55C 7V5 0 50W diode zener 7V5 D0003 301254 DIODE 1N 4148 AXIAL diode 1N 4148 D0004 307916 DIODZ BZX 55C 7V5 0 50W diode zener 7V5 D0005 301254 DIODE...

Page 22: ...2SA 1837 transistor 2SA 1837 Q0041 351982 TRANS MJL 1302 A transistor MJL 1302 A Q0042 331658 TRANS MJ 15023 transistor MJ 15023 Q0043 331658 TRANS MJ 15023 transistor MJ 15023 Q0044 331658 TRANS MJ 1...

Page 23: ...C 1011 120 C 5 safety component PTC R0200 348966 WI SO NTC B57164 K101 J 52 safety component NTC R0201 348966 WI SO NTC B57164 K101 J 52 safety component NTC VR001 348674 WI TRI 250 00 OHM LIN pot tri...

Page 24: ...ER 4 8 0 5 connector 4 8mm faston CN18B 343516 FL STECKER 4 8 0 5 connector 4 8mm faston CN19A 343516 FL STECKER 4 8 0 5 connector 4 8mm faston CN19B 343516 FL STECKER 4 8 0 5 connector 4 8mm faston C...

Page 25: ...20MF 63V 5 cap mylar 220nF C0213 335787 KO KER 15 0PF 100V 2 cap ceramic 15pF C0214 329021 KO KER 0 10MF 100V 20 cap ceramic 100nF C0215 329021 KO KER 0 10MF 100V 20 cap ceramic 100nF C0216 304349 KO...

Page 26: ...BZX 79 B 6V8 0 50W diode zener BZX 79 6V8 D0101 334321 DIODZ BZX 85C 15V 1 30W diode zener BZX 85C 15V D0102 301254 DIODE 1N 4148 AXIAL diode 1N 4148 D0103 301254 DIODE 1N 4148 AXIAL diode 1N 4148 D0...

Page 27: ...2 P 2FACH OP IC NE 5532 N I0301 327197 IC NE 5532 P 2FACH OP IC NE 5532 N I0302 327197 IC NE 5532 P 2FACH OP IC NE 5532 N I0600 331340 IC TL 072 CP 2FACH OP IC TL 072 CP I0700 331340 IC TL 072 CP 2FAC...

Page 28: ...or MJE 340 Q0128 348421 TRANS 2N 3906 transistor 2N 3906 Q0129 335763 TRANS 2N 3904 transistor 2N 3904 Q0141 348421 TRANS 2N 3906 transistor 2N 3906 Q0142 348421 TRANS 2N 3906 transistor 2N 3906 Q0201...

Page 29: ...HM K safety resistor 10 Ohm R0040 301674 WI SCH 10 00 OHM 2 00W 5 resistor 10 Ohm 2watt R0043 301674 WI SCH 10 00 OHM 2 00W 5 resistor 10 Ohm 2watt R0144 332306 WI SCH 3 30 KOHM 2 00W 5 resistor 3 3k...

Page 30: ...POL connector male 8 pin C0001 348458 KO EL 2200 000MF 160V 20 cap electrolytic 2200uF 160 C0002 348458 KO EL 2200 000MF 160V 20 cap electrolytic 2200uF 160 C0003 348458 KO EL 2200 000MF 160V 20 cap e...

Page 31: ...electrolytic 2200uF 160 C0004 348458 KO EL 2200 000MF 160V 20 cap electrolytic 2200uF 160 C0005 348458 KO EL 2200 000MF 160V 20 cap electrolytic 2200uF 160 C0006 348458 KO EL 2200 000MF 160V 20 cap e...

Page 32: ......

Reviews: