EVID Surface Mount S Series - X Models
Installation and wiring | en
11
Electro-Voice
Installation Manual
2022-03 | 07 | F.01U.345.358
Figure 3.6:
Junction box
Refer to
–
Installing the speaker, page 8
3.3
Recommended wire gauge
Wiring method which shall be in accordance with:
1.
In Canada, CSA C22.1, Canadian Electrical Code, Part I Safety Standard for Electrical
Installations, Section 32 and ULC-S524, Installation of Fire Alarm Systems;
2.
In the United States, the National Electrical Code, NFPA 70, and the National Fire Alarm
and Signaling Code, NFPA72;
3.
In the EU, national electrical codes apply.
Maximum recommended wiring length (0.5 dB loss)
100 Watt
40 Watt
10 Watt
18 AWG (1 mm
2
)
230 ft
560 ft
2300 ft
16 AWG (1.5 mm
2
)
360 ft
900 ft
3600 ft
14 AWG (2.5 mm
2
)
560 ft
1400 ft
5600 ft
12 AWG (4.0 mm
2
)
910 ft
2300 ft
9100 ft
3.4
Wiring
i
Notice!
The weather cover must be used in all UL1480 and ULC-S541 fire installations.
This speaker cannot be painted when used in UL1480 an ULC-S541 fire installations.
i
Notice!
The weather cover must be used in all EN54-24 fire installations.
This speaker cannot be painted when used in EN54-24 fire installations.