CLARIMAX 1200 DM pH+ LED – Water-filter-system for treatment of heating-system make-up water

1.1.2 Operator obligations

The operator of the unit is responsible for:
- The instruction of the user
- Regular maintenance

1.2 Safety instructions

-> Please read this guide carefully before comissioning and follow the instructions. Keep this guide accessible 
at all times.

-> Personal injury, caused by non-observance of this guide, are not covered by the product liability law.

-> The manufacturer takes no liability for any other damages caused by non-observance of this guide.

Please note:
Safety instructions warn against dangers and help to prevent personal injury and damage to property. Comply 
with the safety instructions for your own safety. The applicable national and international safety regulations 
must be observed. Every operator is responsible for compliance with the regulations applicable to him and must 
make every effort to comply with the latest regulations.

1.2.1 Safety regulations

•  The CLARIMAX water filter system shall only be used by trained service technicians.
•  The manufacturer‘s specifications must be complied with for maintenance and / or replacement of spare 

parts.

•  In case of unauthorized modifications at the device, the CE declaration of the manufacturer expires.
•  The manufacturer takes no liability for damage caused by improper use. Furthermore, the warranty expires.
•  CLARIAMX must not be operated in potentially explosive atmospheres.
•  CLARIMAX must only be used in perfect condition.
•  CLARIMAX must only be used for treatment of tap water with a quality according to the local tap water law. 

Treatment of acids, alkalis, etc. is not permitted.

•  Check the system for possible damage prior use.
•  The intended use within the performance limits must be ensured.
•  Release water pressure from the unit and / or disconnect it from the mains supply before any repairs.
•  Damaged equipment must be put out of service.
•  Repairs should only be done by qualified personel.
•  Observe relevant and binding standards, such as DIN EN 1717; DIN 1988 etc.

1.2.2 Disclaimer

The use must be carried out exactly as desribed in this manual. The manufacturer is not liable for any damage 
including consequential damage that may result from improper installation or misuse of the product.

Summary of Contents for Clarimax

Page 1: ...User Guide Water Filter System for Treatment of Heating System Make Up Water Water Treatment ...

Page 2: ...LARIMAX 1200 DM pH 5 2 Assembly Commissioning 2 1 System overview 6 2 2 Scope of delivery 7 2 3 Assembly of pressure container and container head 7 2 4 Assembly of inlet and outlet 7 3 Operation Handling 3 1 General note 8 3 2 Comissioning 8 3 3 Filling of heating systems 8 3 4 In line water correction 8 3 5 Capacity control 8 3 5 1 Integrated conductivity measurement 9 3 5 1 1 Battery and mains o...

Page 3: ...ar Anyone working with this device must read this manual completely and follow the instructions In addition to the operating instructions the locally applicable regulations for accident prevention and for safe and professional work must be considered The manufacturer of the water treatment systems recommends to run a written documentation at the side of use The user should record the date of filli...

Page 4: ...r system shall only be used by trained service technicians The manufacturer s specifications must be complied with for maintenance and or replacement of spare parts In case of unauthorized modifications at the device the CE declaration of the manufacturer expires The manufacturer takes no liability for damage caused by improper use Furthermore the warranty expires CLARIAMX must not be operated in ...

Page 5: ...IN EN 1717 at the inlet of CLARIMAX If the water pressure is higher than 6 9 bar a pressure limiter should be installed at the inlet of the water treatment system It is generally recommended to use a pressure limiter when filling heating systems At the water inlet of the filter head a DVGW model tested backflow preventer according to DIN EIN 13959 is factory installed The installation of all parts...

Page 6: ...r system 4 C to 50 C Ambient temperature for storage and transport dry new filter system 20 C to 50 C Nominal flow rate filter cartridge DM pH approx 300 l h at a pressure drop of 1 2 bar Weight dry wet 18 kg 24 kg Capacity 744 L at 500 µS cm conductivity of untreated tap water Dimensions Width Depth Height 288 255 550 mm Total system Operating position vertical Inlet connection G 3 4 Outlet conne...

Page 7: ...peration of this device Attention Please pay attention to the technical data and to the operation and security instructions prior assembly and comissioning After storage below 0 C Note Store only new dry cartridges below 0 C the product need to be stored at room temperature for at least 24 hours Chapter 2 Assembly Comissioning 4 5 Page 6 www elector water treatment com CLARIMAX 1200 DM pH LED Wate...

Page 8: ... head 3 counter clockwise lift it to the top to remove it from the housing Remove the red transport cap from the filter cartridge 2 and check the o ring seals for correct installation integrity and cleanliness Place cartridge 2 in pressure housing 1 Place both feet on the floor brackets 4 Place filter head 3 in position INSERT at pressure housing 1 Turn the filter head clockwise until it snaps bac...

Page 9: ...in a single flow through principle The inlet of CLARIMAX is to be connected to the mains tap water supply and the outlet of CLARIMAX with the heating system Once the water has passed CLARIMAX it has the quality according to the guidelines We recommend to install a system separator or a compact filling armature at the inlet of the CLARIMAX filter system 3 4 In line water correction You even can tre...

Page 10: ...n and charging of the battery pack 3 5 1 1 Battery and mains operation All functions are independently from the power supply The batteries are not charged in the state as delivered and therefore should be charged for at least 24 hours You can operate CLARIMAX either in mains supply mode with the power adapter or in battery mode A fully charged battery allows 48 hours operation You can find the con...

Page 11: ...hausted and that a replacement of the cartridge will soon be necessary The quality of the treated water is still within the range of VDI 2035 The third area is divided into 3 red LEDs All LEDs start flashing accompanied by an acoustic signal The yellow LEDs turn of The filter cartridge is exhausted and need to be replaced The quality of the water does not comply with VDI 2035 anymore 3 5 1 3 Stand...

Page 12: ...also confirmed acoustically The continuous measurement is only recommended in mains operation 3 5 1 6 Battery capacity The remaining battery capacity indicates the charge statues of the integrated rechargeable battery As the number of highlighted LEDS decreases the charge level decreases From green to red The 3 red LEDS always stay on and represent a critical state of charge The mains power adapte...

Page 13: ... can be disposed in accordance with local regulations 3 7 Warranty The CLARIMAX 1200 DM pH LED filter system is subject to the statutory warranty of 2 years A warranty claim can only be asserted if all instructions in this manual are followed and observed Damage caused by improper changes use or grossly negligent damage to the product are not covered by the warranty Malfunctions due to incorrect o...

Page 14: ...Page 13 www elector water treatment com CLARIMAX 1200 DM pH LED Water filter system for treatment of heating system make up water ...

Page 15: ...Page 14 www elector water treatment com CLARIMAX 1200 DM pH LED Water filter system for treatment of heating system make up water ...

Page 16: ...elector GmbH Düsseldorfer Straße 287 42327 Wuppertal Germany Phone 49 0 2058 1790863 Fax 49 0 2058 1790864 E Mail info elector gmbh de Internet www elector water treatment com Water Treatment ...

Reviews: