Elecsys Tracker LT Quick Start Manual Download Page 1

Elecsys Tracker LT -- Test Post and Critical Bond Installation   

Quick-Start Guide

TRACKER LT TEST POINT  

INSTALLATION PROCEDURE

Step 1: Determine if the unit will be 

mounted on the top of the test point 

post or on the side of the post.

(For top of post mounting

, prep 

the unit by feeding the cable through 

the hole in the top of post adapter, 

then using the screws, washers, and 

nuts provided secure the adapter to 

the unit.)  

(For side of the post mounting

prep the unit by rerouting the signal 

cable from the bottom of the unit to 

the side of the unit. Remove the 4 

screws in the top of the unit to gain 

access inside and swap the cord 

grip and plug already in the unit. 

Replace the top and secure with the 

4 screws.) 

Step 2: Cut the cable to the proper 

length for the test site and connect 

the wires per the wiring diagram be-

low (Brown, Yellow, & optional Blue/

White wires). NOTE: Be sure to use 

electrical tape to insulate unused 

wires to eliminate possible shorts or 

errant grounding.

Step 3: 

For top mount installation

 

insert excess wire inside of post and 

place top of post adapter in position 

on the post. Use self-tapping screws 

(not included) to secure the Tracker 

LT unit to the post. 

For side mount 

installation

 secure cable to post or 

wall to allow for strain relief of the 

connections.
Step 4: Call customer support to 

configure the site.

TRACKER LT  

CRITICAL BOND INSTALLATION 

GUIDE

Step 1: Prep the unit by rerouting 

the signal cable from the bottom of 

the unit to the side of the unit. 

Step 2: Remove the 4 screws in the 

top of the unit to gain access inside 

and swap the cord grip and plug 

already in the unit. 

Step 3: Thread cabling through cord 

plug in the side of the unit. 
Step 4: Replace the top and secure 

with the 4 screws. 

(continued on other side)

Package contents:  Tracker LT Monitor Unit including connection harness cable and 

antenna plus an adapter for 3” riser pipe installations.  

 

*Please inspect package contents and immediately notify Elecsys Technical Support 

at (913)825-6366 or email [email protected] if there are any discrepancies.

Installation Notes:  Prior to beginning installation of this product, locate the serial num-

ber of the device on the label attached to the back of the enclosure and record it for 

use in setting up the website with customer service.

IMPORTANT:  Do not delay installation.  Communication billing for this unit begins 

upon installation or 90 days following product shipment, whichever comes first.  

Ser. #______________________

Call Elecsys Customer Support for installation help - (913) 825-6366

Go to www.elecsyscorp.com/Installation for videos and manuals.

Copyright 2017 Elecsys Corporation  81-0059-00 Rev D