Part names
Power button
Level display
Enter button
Display
panel
Battery cover
Right button (forward)
(Press to switch the power on or off. The
power also switches on when you step on the
analyser. In such cases, the user number is
recognized automatically.)
Left button
(Back)
Display
section
(Displays the evaluation result.)
(Press to register, edit, or check users. Press to enter
settings during configuration. Press and hold to return
to the previous setting.)
(Press and hold
to change
quickly.)
(Press and hold to change quickly.)
Using the analyser
Place the analyser on a hard flat surface, such as a wooden floor.
Do not place the analyser on any of the following surfaces. Doing so may cause errors in the
measurement values.
• Sloped floor
• Soft surface, such as a rug
Precautions
The power is switched on and measurement is started by
simply stepping on the analyser. Accordingly, the analyser is
calibrated automatically to 0.00 kg periodically while the power
is switched off. However, calibration may not be performed
correctly in the situations listed below. Before using the
analyser for measurement,
always place the analyser on a
hard surface with nothing on top of the analyser, and then
press either the Power button ( ) or Enter button ( ).
• The analyser was stored standing up
• The analyser was stored with something on top of the
analyser
• The analyser was picked up and moved
When the measurement values are obviously incorrect, perform the following procedure, and then measure again.
The following 3 methods can be used to measure with this analyser.
The power is switched on and measurement is started by simply stepping on the analyser.
In addition, the user is recognized automatically from the registered users, and the measurement
results are recorded. (Limited to when the user number has been specified and measurement
has been performed at least once in the past.)
Specify the number of a registered user, and then measure. The user is matched reliably with
their registered data (more so than with automatic user recognition), and then the measurement
results are displayed. For the user registration and measurement methods, see pages 5 to 8.
An unregistered user can be measured. The measurement values cannot be recorded. For the
measurement method, see page 6.
(Low)
(Normal)
(High)
Troubleshooting
Body composition analyser
Manual
(Quick guide)
HCS-FS02 series
Elec-
trodes
Elec-
trodes
Inserting the batteries
Placing the analyser
Measuring body composition
The automatic 0.00 kg calibration and
correction function
Weight mode button
(Press when measuring only your weight,
or the weight of a baby or pet.)
Displays the difference in weight between the 1st and 2nd measurements to
measure the weight of a baby or pet. For the measurement method, see page 7.
Measures only your weight. For the measurement method, see page 7.
Measuring the weight of a baby or pet
Measuring only your weight
Problem
Check points
“
” appears on the display section
Switch or exchange the batteries.
“
” (error) is displayed
“
” (error) is displayed
Did you step on the analyser during automatic correction (
)?
Did you move during measurement? How is your standing
position or posture?
Are the bottoms of your feet dirty?
Did you try to measure with socks or other footwear still on?
“
” (error) is displayed during
measurement
Step on while the power is off
Measuring
User number is displayed
Measure after automatic recognition of the user
Measure after specifying the user number
Measure using Guest mode
On the rear surface of the analyser, push
the battery cover in the direction of the
arrow, and then remove it.
Attach the battery cover.
Insert the 3 included size AAA batteries
after checking the polarity ( / ). The
side with the spring is the negative ( )
side.
Make sure that “ ” is displayed.
Do not place anything on the analyser
or apply weight to the analyser while
“ ” is displayed.
Press either the Power button (
) or
Enter button (
).
Place the analyser on a hard flat
surface.
Press the Enter button (
).
Make sure that “0.00kg” is
displayed.
Press the Power button (
) to
switch off the power.
DANGER
WARNING
Never use this product with the following
medical electronic devices.
(1) Pacemakers and other implantable
medical electronic devices
(2) Heart-lung machines and other artificial
life-support medical electronic devices
(3) Electrocardiographs and other
wearable medical electronic devices
This analyser passes a weak electric current
through the body and may cause the
above-mentioned devices to malfunction,
resulting in an accident or serious injury.
•
Never judge the measurement results yourself (or do such things as
evaluate measurements or base an exercise plan on this).
•
Weight loss and therapeutic exercise based on self-judgment may be
bad for your health. Always follow the instructions of a certified
professional.
•
Do not step on the edge of the analyser, jump on the analyser, or
jump up and down on the analyser. Doing so may cause you to fall or
slip, resulting in serious injury.
•
Do not use the analyser on a slippery surface, such as a tile surface
or wet floor.
Doing so may cause you to fall or slip, resulting in serious injury.
Furthermore, water may get inside the analyser and cause a breakdown.
•
Never modify, disassemble, or repair the analyser. This may cause an
unexpected accident or other trouble.
* This manual is only a quick guide.
For greater details, see the manual included
with the product.
Operation section
Battery exchange display
(Switches on when the battery must be replaced.)
Operation confirmation display
(Switches on if an operation button is pressed.)
* For use in Japan only.